TEMPERATURE CONTROLLER

STORM 

ST

201

08

▶ Press       and then      until 

[Loc] 

appears.

 

▶ Press      and 

[OFF] 

will appear.

This function blocks changes to the controller by displaying the symbol     when activated. This lock can 

be total or partial, according to parameters 

P45

 and 

P46

.

Shortcut tip: 

You can deactivate the lock by turning the controller off and then on again by pressing the 

key      until 

[LOC] [OFF]

 is shown in the controller display.

3.4. [LOC] - LOCKING FUNCTIONS

▶ Press        and then       to 

[SP] 

▶ Press  
▶ With the keys       , edit the desired temperature value in the Normal SETPOINT
▶ Press       to save

3.6. [SP] - EDIT NORMAL SETPOINT

▶ Press       and then       to 

[SPE] 

▶ Press
▶ With the keys       , edit the desired temperature value in the Economic SETPOINT
▶ Press      to save

3.7. [SPE] - EDIT ECONOMICAL SETPOINT

▶ Press       and then       until 

[CTL] 

▶ Press      and 

[OFF] 

will appear.

Activates the control functions shutdown function and starts acting as a temperature display. 

Information: 

This function depends on the parameters configured in 

P44

3.5. [CTL] - TURNS OFF CONTROL FUNCTIONS

▶ Press       and then       until 

[CR9] 

is displayed

▶ Press       to clear the minimum and maximum temperature registers recorded

3.8. [CR9] - CLEARING MIN AND MAX REGISTERS

Summary of Contents for STORM ST201

Page 1: ...01 ENGLISH REV 02 USE FOR COLD STORAGE ROOMS AND VISA COOLERS ELECTRICAL AND HOT GAS DEFROSTING FRONT PANEL IP65 ECO AND SUPER FREEZING MODE PROGRAMABLE BY NFC APP EVEN UNPLUGGED BUZZER SHORTCUT KEYS...

Page 2: ...3 Easy Menu Features 3 1 SUF Activate Super Freezing Mode 3 2 Eco Select Eco Mode 3 3 Dfr Manual defrost 3 4 Loc Lock Functions 3 5 Ctl Control Functions Off 3 6 SP Edit Normal Setpoint 3 7 SPE Edit E...

Page 3: ...al design that harmonizes with various types and colors of equipment Front Panel IP65 Ambient temperature sensor for ON OFF Compressor Defrost sensor for monitoring the evaporator temperature Temperat...

Page 4: ...te electromagnetic interference such as motors meters relays and solenoids IMAGE 1 Easy Key Upper Key Lower Key Enter Key Fan Control Locked Functions Off Temperature Unit Indication Degrees Celsius C...

Page 5: ...via the application or directly through the front keys of the controller The number of different con gurations with the Emicol Easy App is unlimited depending only on the memory capacity of the cell p...

Page 6: ...plete parameter menu 231 Change the unit of measure to Celsius or Fahrenheit The parameters are retained this change will not reset to the factory settings Shortcut tip Press the keys simultaneously t...

Page 7: ...sed time to enter economic mode If P42 configured as Digital input P29 Maximum time in economic mode 3 2 ECO ACTIVATE ECO MODE Press and then to dFr Press and ON and the symbol will appear Shortcut ti...

Page 8: ...SP Press With the keys edit the desired temperature value in the Normal SETPOINT Press to save 3 6 SP EDIT NORMAL SETPOINT Press and then to SPE Press With the keys edit the desired temperature value...

Page 9: ...er P43 Instantaneous temperature at sensor S3 If enabled in parameter P42 3 10 INFORMATION ABOUT THE PROCESS IN PROGRESS CRTL Press until appears CRTL turns controller functions on off LOC pressed tog...

Page 10: ...9 Evaporator temperature S2 for fan return after draining 105 50 C 30 P22 Fan stop for high temperature in evaporator 30 0 NO min 1 P20 Maximum time for fan return after drainage fan delay 15 0 NO min...

Page 11: ...at any time to exit the mode and restart the controller Simultaneously press the to return to the selection menu between controlling the outputs or display inputs 11 USER MANUAL TEMPERATURE CONTROLLER...

Page 12: ...sword P06 Instrument powering on delay It delays the process start to avoid several devices turning on at the same time Note During the delay only the temperature will be shown in the display while al...

Page 13: ...ps the compressor on Option 2 Cycles according to the times of P32 and P33 P12 Defrost at start of instrument This parameter allows you to set an additional defrost when starting the controller useful...

Page 14: ...In this period all the outputs remain off To disable adjust time 0 no P19 Evaporator temperature S2 for fan return after draining It is the maximum temperature at Sensor 2 to turn the fan on again af...

Page 15: ...ol to turn the compressor on and off P27 Control differential economic ECO hysteresis It is the temperature difference between ON and OFF the compressor output in ECONOMIC mode MODE P28 Time for close...

Page 16: ...shut down control outputs Turns off all outputs if the S3 sensor reaches a higher temperature de ned in the parameter This parameter is voided until the Setpoint is reached the rst time The warning Ah...

Page 17: ...N Setpoint ECO N O 3 Digital IN Defrost N O 4 Digital IN Super Freezing N O 5 Digital IN External alarm N O 6 Digital IN Door contact N O 7 Digital IN Setpoint ECO N C 8 Digital IN defrost N C 9 Digit...

Page 18: ...tion The ST201 2HP controller will be able to work with different types of temperature sensors avoiding the need for exchanging in cases of dif culty when cabling Example cold rooms SF9 Standard SCL O...

Page 19: ...In Economic mode Fan delay process Locked Functions Activates function lock Sensor1 error Disconnected damaged or short circuited Sensor2 error disconnected damaged or short circuited Sensor3 error D...

Page 20: ...an generate dangerous or harmful situations for people Emicol guarantees the product and is exempted from any and all extra expenses such as inputs services or transportation 10 WARRANTY AND REPAIRS D...