P5-08
AO2 output function
selection
4: Output power
5: Output voltage
6: Pulse input ( 100% corresponds to 100.0Hz)
7: AI1
8: AI2
9: Keyboard potentiometer
10: Length
11: Count value
12: Communication settings
13: Motor speed
14: Output current (100.0% corresponds to
1000.0A)
15: Output voltage (100.0% corresponds to
1000.0V)
16: Output torque (torque actual value)
1
√
P5-09
FMP maximum
frequency
0.01kHz
~
100.00kHz
50.00kHz
√
P5-10
AO1 zero bias
coefficient
-100.0%
~
+100.0%
0.0%
√
P5-11
AO1 gain
-10.00
~
+10.00
1.00
√
P5-12 AO2 zero bias
-100.0%
~
+100.0%
0.0%
√
P5-13 AO2 gain
-10.00
~
+10.00
1.00
√
P5-17 FMR output relay time
0.0s
~
3600.0s
0.0s
√
P5-18
RELAY1 output relay
time
0.0s
~
3600.0s
0.0s
√
P5-19
RELAY2 output relay
time
0.0s
~
3600.0s
0.0s
√
P5-20 DO1 output relay time
0.0s
~
3600.0s
0.0s
√
P5-21 DO2 output relay time
0.0s
~
3600.0s
0.0s
√
P5-22
DO output terminal
valid state selection
0: Positive logic
1: Negative logic
Bits: FMR
Ten’s bit: RELAY1
Hundreds’s bit: RELAY2
Thousands’s bits: DO1
Ten thousands’s bit;s: DO2
00000
√
P6 Group start and stop control
P6-00 Starting mode
0: Directly start
1: start after speed tracking
2: Pre-excitationstart (AC asynchronous
machine)-
0
√
P6-01 Speed tracking mode
00: starts from stop frequency
1: starts at zero speed
2: Starting from the maximum frequency
0
╳
P6-02 The speed of speed tracking 1
~
100
20
√
P6-03 Starting speed
0.00Hz
~
10.00Hz
0.00Hz
√
P6-04 Starting speed keeping time 0.0s
~
100.0s
0.0s
╳
P6-05
Start DC braking current /
pre-excitation current
0%
~
100%
0%
╳