Reset of the manipulation register and creation of pre-values
a) Reset when reading out via the optical interface D0
With a readout via the optical interface D0
the „hand symbol“ in the display or an
activated alarm is deleted.
Note:
No pre-value is formed.
b) Reset with a remote readout via the electrical interface
The reset via the electrical interface takes place analogue to the reset via the optical
interface.
c) Automatic reset
At the end of the billing period an automatic reset takes place in the pre-value
registers C.51.5*00() and C.52.5*00() and also C.51.6*00() and C.52.6*00().
A „hand symbol“ in the display or an activated alarm are still activated after the reset.