background image

 

926001 en ma 2013

TFX Serie

 

 

     Serie 430

     Serie 430

English

3.2.2 Menu 

operation 

Select the next menu option 
with the right key (4). 

Select the previous menu option 
with the left key (3). 

Carry out and store the current 
menu option with the down key 
(5).

Exit the menu with the ON/OFF 
key (2). The device switches 

 .

AL HI 

 

Upper limit value of  

  

 

desired 

range

   

 

Press centre key =  

  

 

unblock

   

 

Press left/right keys =  

  

 

increase/decrease 

up 

   

 

per limit value

   

 

Press centre key =  

   

 

store upper limit value  

   

 

and block changes

SCAL  

Activation/Deactivati- 

   

 

on of the special ad- 

  

 

justment

   

 

ON = Activated   

  = Deactivated

   

 

Press centre key =  

   

 

ON/OFF of special ad- 

  

 

justment

°C

Summary of Contents for Ebro TFX 926001 Series

Page 1: ...926 001 DIGITAL THERMOMETER MANUAL 926001 en ma 2013 Thermometer TFX Serie...

Page 2: ...that this product ful lls CE guidelines ed by NSF exept TFX 430 ed by UL This product fulfills the guidelines in accordance with EN 13485 Suitability S Storage T Transport Location A Food storage and...

Page 3: ...ration 1 4 1 Switching on thermometer 1 4 2 Display 1 4 3 Measuring temperature 1 4 4 Measurement memory 2 4 4 1 Retrieving memory contents 2 4 4 2 Storing current value 2 4 4 3 Deleting measurement m...

Page 4: ...fety notes t Never expose the device to high tem peratures 60 C 140 F t Under no circumstances measure live components with this device and external sensors t Do not use the device in explosion endang...

Page 5: ...8 0 Fax 0841 9 54 78 80 E mail info ebro de Internet http www ebro de Parts list Thermometer with t Sensor cate t Instruction manual t For accessories see appendix I 1 3 Cautions The thermometer TFX s...

Page 6: ...asu rement precision and linearity over the entire measurement range You may attach a range of ebro sensors to the thermometer TFX 410 1 and TFX 430 selecting the one most suitable for your technical...

Page 7: ...s dis played for approx 1 second 3 Release the ON OFF key 2 as soon as device model TFX is displayed Then keep the lower key depressed until USER followed by MENU is displayed The device now enters th...

Page 8: ...he automatic switch off if prolonged measurements are required with the model TFX 420 430 ALARM Tu r n a l a r m f u n c t i o n ON Alarm function turned on OFF Alarm function Press centre key Turn al...

Page 9: ...ent menu option with the down key 5 Exit the menu with the ON OFF key 2 The device switches AL HI Upper limit value of desired range Press centre key unblock Press left right keys increase decrease up...

Page 10: ...itches to measuring mode and the first measurement reading is displayed in C The thermometer is now ready for use If an error message is displayed please refer to chapter 6 What do I do if 4 2 Display...

Page 11: ...eous measurements Wait until the measured value has stabilised The trend display shows a downward pointing triangle for decreasing 4 temperatures and an upward pointing triangle for increasing 3 tempe...

Page 12: ...ed along with the lowest measurement of the current measu ring Press the key MIN MAX again MAX is displayed along with the largest measurement value in the current measuring Press MIN MAX again to ret...

Page 13: ...or downwards by pulling at the plug in connector Do not turn 3 Plug in a new probe or extension cable where required E n s u r e the connection is secure The connector must be engaged 4 Slide the prot...

Page 14: ...ring range exceeded Probe defective Plugin connection jack plug Consider measuring range Call service Check connection plug has to snap in Below measuring range Short circuit of sensor Consider measur...

Page 15: ...ration t The calibrated thermometer will be returned within one week 8 Servicing and waste disposal 8 1 Cleaning Clean the device with a damp cloth Do not use any solvents such as Aceton as they corro...

Page 16: ...oth plastic plugs 1 with a sharp implement needle etc Using a suitable cross head screwdriver PZ 1 remove both the visible cross head screws 2 Hold the bottom of the thermometer 6 in one hand and remo...

Page 17: ...Probes in various specs available on request Reassemble the thermometer in reverse order noting the correct tightening tor que of 0 4 Nm To ensure device is fully water tightness make sure the seal b...

Page 18: ...erature 30 to 70 C 22 to 158 F Resolution 0 1 C 0 2 F ResolutionTFX430 0 01 C 0 02 F at 100 00 to 199 99 C F and 0 1 C 0 1 F for the rest Measuring precision Series 410 420 0 3 0 3 F Series 430 50 00...

Page 19: ...bezieht mit der folgenden Richtlinie bereinstimmt to which this declaration refers complies with the following guideline auquel cette d claration se r f re est conforme aux directive Pr fstellen Insp...