Programming. Calibrating the temperature sensor - SERVICE
CALIBRATING THE TEMPERATURE SENSOR. 90
o
C recommended.
1.
Press buttons (symbol) and (symbol) at the same time for 5 seconds
and until you hear 2 beeps.
The display shows the current setting.
Adjust using the buttons (symbol) and (symbol).
2.
Press (symbol) and (symbol) at the same time to save the current
setting.
NOTE The current temperature in the water tank must be entered when calibrating.
Adjust
Signal
98°
-2
97°
-1
Max.
96°
0
95°
1
94°
2
93°
3
92°
4
91°
5
Av
6
ON