Autotune
(cont)
•
A rotating auto-tune should only be used if the motor is
uncoupled. A rotating auto-tune first performs a stationary auto-
tune before rotating the motor at
2
/
3
base speed in the direction
selected. The rotating auto-tune measures the power factor of
the motor.
To perform an auto-tune:
•
Set Pr
00.040
= 1 for a stationary auto-tune or set Pr
00.040
= 2
for a rotating auto-tune
•
Close the Drive Enable signal (terminal 11 and 13). The drive
will display ’Ready’.
•
Close the run signal (terminal 7 or 8). The lower display will
flash ’Autotune’ while the drive is performing the auto-tune.
•
Wait for the drive to display ’Ready’ or ‘Inhibit’ and for the motor
to come to a standstill.
•
Remove the drive enable and run signal from the drive.
Save
parameters
Select 'Save Parameters' in Pr
mm.000
(alternatively enter a value
of 1000 in Pr
mm.000
) and press red
reset button or toggle
the reset digital input.
Run
Drive is now ready to run