background image

TS1 Series 

Temperature Controls 

Alco Controls 

D

A

T

A

S

H

E

E

T

TS1__35038_EN_R05.doc 

4 / 8 

10.08.2011

 

Nomenclature 

The following chart explains the nomenclature of the TS1 
controls for ease of reference. The basic structure is that of a 
three digit 

Product Name

 followed by a three digit code, 

describing 

Function, Temperature Range 

 and 

Temperature 

Sensor. 

Customised versions, which deviate from standard catalogue 
products are available on request and use a different 

Product 

Name.

 They are called 

TSA

 followed by the three digit code to 

indicate 

function, temperature range

 and

 temperature sensor

.

Technical data 

 

Environmental conditions 

Electrical contacts 

Ambient temperatures 

 

 

Type of contacts 

1 x SPDT contact 

storage and transportation:

operation:

-50 °C to +70 °C 
-50 °C to +70 °C 

 

Contact material 

- standard:

- options:

CuAg

3

gold plated contacts 

Maximum temperature at sensor bulb depending on bulb  

 

Heating load (AC1): 

  24A / 230 V AC 

Locked rotor / Startup (AC3): 

144A / 230 V AC 

type and charge 

 

Inductive load (AC15): 

  10A / 230 V AC 

Dust and water protection 

 

EN 60529 / IEC 529:  

 

Control mounted flush against wall!

IP44 (w/o off-switch) 
IP30 (with off-switch) 

 

Inductive load  (DC13): 

 0.1A / 230 V DC 
  3A / 24 V DC 
  6A / 12 V DC 

Vibration resistance: 

4 g @ 10 … 1000 Hz

Motor rating UL (FLA): 

  24A / 120/240V AC 

Approvals 

 

Locked rotor UL (LRA): 

144A / 120/240V AC 

Low Voltage Directive 

all models 

 

Bellows heater (sensor types A, E, P -

73/23/EWG 93/68/EWG;  
EN 60947-1 / 60947-5-1 / 60730-2-9 

(CE-Label) 

 

not for frost monitors function C or D):

- option:

82 k , 230V AC, DC 
12V, 24V  rating 

Germanic Lloyd: 

standard models 

 

Materials 

when used with marine cable glands (accessory) 

 

Housing materials  

cover: Polycarbonate (PC) 

UL / CSA: 

all models 

(pending)

 

frame: Steel, yellow chromated 

Type code

TS1 -

Function / housing variant

A

= Wall mounting, top adjustment 

B

= Wall mouting, top adjustment, off-switch 

C

= Frost monitor, auto reset 

D

= Frost monitor, manual reset 

E

= Wall mounting, front adjustment 

F =

Wall mounting, front adjustment, off-switch 

G

= Flush mounting 

H

= Flush mounting, off-switch 

R = Wall mounting, top adjustment, manual reset* 

*

temp. ranges 0 – 4: manual reset for falling temperature 

 temp. ranges 5 – 9: manual reset for rising temperature 

Temperature Sensor Type

A

= Vapour charge, 2 m, bulb 

E

= Vapour charge, 0 m, coil 

F

= Adsorption charge, 2 m, bulb 

P

= Vapour charge, 2 m, capillary    

 

function „C“ and „D“: 6 m capillary

 

Temperature range

0

=

+4.5 … + 20 °C 

1

=

-45 … -10 °C 

2

=

-30 … +15 °C  (-30 … +10 °C) 

3

=

-10 … +35 °C  (-10 … +25 °C) 

4

=

-25 … +30 °C   (-30 … +35 °C) 

5

=

+20 … +60 °C  (+25 … +75 °C) 

6

=

+50 … +100 °C 

7

=

0 … +10 °C 

() = 

dep. on exact version 

Product Name

TS1 

= Adjustable thermostat 

TSA

 = Customised version

 

Summary of Contents for TS1 Series

Page 1: ... delivered in three main housing variants top operated front operated and flush mounted Top operated controls have adjustment spindles at the top and a display scale indicating temperature setpoint and differential at the front A knob which may be permanently plugged onto one of the adjustment spindles comes with every control Frost monitors and room thermostats are derivatives of top operated the...

Page 2: ...spond faster to temperature changes than adsorption and liquid charges Adsorption charge sensor type F Adsorption charged sensor types operate on the basis of a temperature dependent adsorption material which is located inside the bulb only Therefore these sensor types always respond to temperature changes at the bulb only This makes them suitable to applications where it is not always defined whi...

Page 3: ... again Manual reset low pressure contact function Manual reset high temperature On increasing temperature above the upper setpoint contacts 1 2 open contacts 1 4 close and latch Only on falling temperature below lower setpoint and after pressing the manual reset button contacts 1 4 will open and contacts 1 2 will close again Manual reset high temperature contact function For operational safety all...

Page 4: ...30 V DC 3A 24 V DC 6A 12 V DC Vibration resistance 4 g 10 1000 Hz Motor rating UL FLA 24A 120 240V AC Approvals Locked rotor UL LRA 144A 120 240V AC Low Voltage Directive all models Bellows heater sensor types A E P 73 23 EWG 93 68 EWG EN 60947 1 60947 5 1 60730 2 9 CE Label not for frost monitors function C or D option 82 k 230V AC DC 12V 24V rating Germanic Lloyd standard models Materials when u...

Page 5: ...l dimensions and drawings TS1 Axx Bxx Cxx Dxx TS1 Exx Fxx TS1 Gxx Hxx Sensor type A Vapour charge 2 m capillary with bulb Sensor type P Vapour charge 2 m capillary 6m with function C or D Sensor type E Vapour charge coil 0 m Sensor type F Adsorption charge 2 m capillary with bulb 54 70 Ø 9 2 2 5 Ø 9 5 70 Ø 22 ...

Page 6: ... 351 800 30 35 2 8 20 35 5 0 and Defrost and Universal Thermostat 100 Adsorption bulb TS1 A5F 4 458 400 20 60 3 10 10 35 30 Thermostats with Off Switch TS1 B1A 4 366 700 45 10 55 18 20 2 m TS1 B2A 4 366 800 30 15 1 5 16 36 1 6 150 Vapour capillary TS1 B3A 4 366 900 10 35 23 3 2 and TS1 B4F 4 367 000 30 35 2 8 20 35 5 0 100 Adsorption bulb Room Thermostats TS1 Top Operated with coil type sensor Roo...

Page 7: ...pe sensor Room Thermostats without Off Switch including insulation console TS1 E1E 4 365 300 45 10 2 16 55 18 20 0 m TS1 E2E 4 356 800 30 10 1 5 15 36 4 2 70 Vapour coil TS1 E3E 4 356 900 10 25 1 5 15 23 20 18 Room Thermostats with Off Switch including insulation console TS1 F1E 4 368 000 45 10 2 16 55 18 20 TS1 F2E 4 368 100 30 10 1 5 15 36 4 2 70 Vapour 0 m TS1 F3E 4 368 200 10 25 1 5 15 23 20 1...

Page 8: ...ations failures may occur The suitability for this has to be assured from the plant manufacturer which may include making appropriate tests Since conditions of use are outside of ALCO S control we can not assume any liability for results obtained or damages occurred due to improper application This document replaces all earlier versions Emerson Electric GmbH Co OHG ALCO CONTROLS Postfach 1251 Heer...

Reviews: