6
TESCOM™ Safety, Installation, Operations & Service Manual
Content
December 2020
Installation Manual
TR000238ENUS-01_12-20
•
Some fluids when burning do not exhibit a visible flame. Use extreme caution
when inspecting and/or servicing systems using flammable fluids to avoid death or
serious injury to personnel. Provide a device to warn personnel of these dangerous
conditions.
•
Many gases can cause suffocation. Make certain the area is well ventilated. Provide a
device to warn personnel of lack of Oxygen.
•
Never use oil or grease on these regulators, valves, or accessories unless
recommended as specified in Operations and Service procedures. Oil and grease are
easily ignited and may combine violently with some fluids under pressure.
•
Have emergency equipment in the area if toxic or flammable fluids are used.
•
Upstream filters are recommended for use with all fluids.
•
Do not bleed system by loosening fittings.
•
Prevent icing of the equipment by removing excess moisture from the gas.
•
Always use proper thread lubricants and sealants on tapered pipe threads
.
Intended Use
Regulators: Pressure regulators are intended to be used to regulate the pressure at which
fluids are administered in an application. Additional regulations that supplement or limit
the intended use may apply depending on the regulator and media or industry-specific
standards. Regulators are not intended for use as a pressure or safety relief valve.
Valves: TESCOM Valves are intended to be used to control gas flow in piped systems. They
are not intended for use as a pressure reducer.
Installation
CAUTION
Do not open packaging until ready for installation or in a clean environment. Product is
cleaned in accordance with CGA 4.1 and ASTM G93, Verification Type 1, Test 1 and Test 2.
With periodic verification of cleaning process to MIL-STD-1330D.
WARNING
Make sure that the components and materials used in the fluid handling system are
compatible with the fluid and have the proper pressure rating. Failure to do so can result in
death, serious injury, and/or property damage.
Inspect the regulator, valve, and accessories for physical damage and contamination. Do
not connect the regulator, valve, or accessory if you detect oil, grease, or damaged parts. If
the regulator, valve, or accessory is damaged, contact your local TESCOM representative to
have the regulator cleaned or repaired.
2.1.1
2.1.2