10
TESCOM™ 44-6800 E Series
Content
October 2020
Installation, Operations and Maintenance Manual
TR000058ENUS-02_10-20
j.
Adjust the temperature with the TRIM1 potentiometer. TRIM1 potentiometer, located
on the electrical board, provides a 270° of adjustment. The temperature set point
range is from 50 °C /122 °F (fully counter clockwise position) to 400 °C /752 °F (fully
clockwise position). See Figure 3.
Product does not provide actual media temperature. Actual media temperature
should be taken from a different device.
k.
Heater Temperature Feedback Display (Optional):
The display reads the temperature of the heater in degrees Celsius.
l.
Temperature Set Button (Only with Optional Display):
This button is located on the control board. See Figure 4.
When pressed down the display will show the heater set point temperature.
m.
Place stopping plugs in any unclosed conduit entry.
Figure 2:
Figure 2
Separated assembly is supplied with
electrical housing shipped separately from
the regulator assembly. Extra wire is
provided. Connectors J4 and J2 from the
regulator assembly must be attached to
the corresponding control board terminals.
For integral applications the electronics
enclosure must engage the regulator
assembly by at least 5 full threads made
wrench tight.
(J4)
(J5)
(J2)
(J1)