7. Fold the wires of the wiring harnesses

into the slot in the motor coupling, slide
the hanger pipe down the wires and
seat the hanger pipe in the motor
coupling.

8. Align the clevis pin holes in the hanger

pipe with the holes in the motor
coupling. Install the clevis pin and
secure with the hairpin clip. The clevis
pin must go through the holes in the
motor coupling and the holes in the
hanger pipe (Figure 6). Push the
straight leg of the hairpin clip through
the hole near the end of the clevis pin
until the curved portion of the hairpin
clip snaps around the clevis pin. The
hairpin clip must be properly installed to
prevent the clevis pin from working
loose. 

9. Install the setscrew (supplied in loose

parts bag supplied with ceiling fan) in
the motor coupling and tighten using
the 5/32" setscrew wrench (supplied
with ceiling fan) (Figure 6). A loose
setscrew could cause the fan to
wobble.

10. Screw the two threaded studs (select

the proper length stud as described in
the Ceiling Fan Owner’s Manual) into
the threaded holes in top of the motor.
(Figure 7). (Early motors have two
threaded brackets.) Coil the wires and

4

4. Push the wiring harness connector

(supplied with the SW375 receiver) and
the connectors on the blue wire
(supplied with the control) and yellow
wire (supplied with fans containing
built-in Uplights) through the hanger
pipe until they extend about 4" out of
the pipe (Figure 4).

5. Cut the harness wires approximately 3"

from the end of the pipe. Strip
insulation 1/2" from end of wires.

6. Using wiring connectors supplied,

connect the white, red, yellow, blue, and
brown wires of the wiring harness to the
white, red, yellow (orange wire for early
CF2400 Models), blue, and brown wires
of the ceiling fan (Figure 5). Wires must
be connected color-to-color.

It is critical that the clevis pin in the
motor coupling is properly installed and
the setscrew securely tightened. Failure
to verify that the pin is properly installed
could result in the fan falling.

WARNING

!

MOTOR
COUPLING

HANGER PIPE

HAIRPIN
CLIP

CLEVIS
PIN

SETSCREW

Figure 6

4"

DOWNROD

CUT HERE

3"

YELLOW LEAD (Built-in Up Light Only) 
(See NOTE 3)

WIRING
HARNESS

BLUE WIRE

Figure 4

BLUE WIRE TO
BLUE WIRE

Off

On

Up

Down

Lights

Fan

Sleep

FAN BLADES REMOVED
FOR CLARITY

HANGER
PIPE

WHITE WIRE

BLACK WIRE

WIRING HARNESS
CONNECTOR

YELLOW WIRE
TO YELLOW
WIRE (Built-in
Up Light Only)

BLUE WIRE TO 
BLUE WIRE

SW375 RECEIVER

TO

120V SUPPLY

BROWN WIRE
TO BROWN
WIRE

YELLOW WIRE
TO YELLOW WIRE*
(Built-in Up Light Only)

SW350
WALL CONTROL 
OR
ON/OFF WALL 
SWITCH

RECEIVER
CONNECTOR

BLACK WIRE 
(NOT USED)

RED WIRE TO
RED WIRE

WHITE WIRE TO
WHITE WIRE

LIGHT
FIXTURE

FAN
HOUSING

* ON SOME CF2400 MODELS,
   THE WIRE FROM MOTOR
   MAY BE ORANGE

Figure 5

BP7253-2  4/28/06  11:58 AM  Page 4

Summary of Contents for SR330

Page 1: ...F2300 1 CF2400 1 CF2454 2 CF2500 1 CF2600 2 CF2650 0 CF2675 1 CF3500 0 CF3900 1 CF4500 4 CF4600 0 and CF4800 3 Off On Up Down Lights Select Fan Sleep Flow Security Model SW350 Wall Control Lights Fan Select Airflow Sleep Security Winter Fan Low Down Light Fan High Up Light Air DN Air UP Model SR330 Remote Control Model SW375 Receiver NOTE The SW350 and SR330 controls must be used with a SW375 rece...

Page 2: ...n tested and found to comply with the limits for a class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to ra...

Page 3: ...T See NOTE 3 REMOVE WIRE CONNECTORS FROM RED AND BROWN WIRES See NOTE 1 3 BLUE WIRE BLACK WIRE WHITE WIRE CAP BLACK WIRE USING A WIRE CONNECTOR REMOVE WIRE CONNECTOR MOTOR COUPLING Figure 1 NOTE 2 On Model CF1 CF2400 and CF2800 Series Ceiling Fans the red and brown wires from the motor are connected to red and brown wires from the reversing switch Remove the wire connectors and separate these wire...

Page 4: ...ellow wire supplied with fans containing built in Uplights through the hanger pipe until they extend about 4 out of the pipe Figure 4 5 Cut the harness wires approximately 3 from the end of the pipe Strip insulation 1 2 from end of wires 6 Using wiring connectors supplied connect the white red yellow blue and brown wires of the wiring harness to the white red yellow orange wire for early CF2400 Mo...

Page 5: ...ed with steps 11 through 19 below 11 Position the ceiling cover over the hanger pipe Figure 8 Be sure the cover is oriented correctly with the large opening at the top 12 Install the hanger ball on the hanger pipe as follows Route the wiring harness connectors through the hanger ball and slide the hanger ball over the hanger pipe Install the pin through the holes at the top of the hanger pipe and ...

Page 6: ... screws from existing switches Pull switches out from wall boxes and determine which wall box contains the hot lead and which wall box contains the load wire Also identify traveler wire s which are common to both wall boxes 16 Connect the black wire from the wiring harness to the black hot supply wire Figure 5 Connect the white wire from the wiring harness to the white neutral supply wiring Connec...

Page 7: ... already connected to the black wire in the other wall box Secure with wire connectors supplied 7 STANDARD WIRING FOR EXISTING 3 WAY CONTROLS HOT BLK TRAVELER WIRES BLACK LOAD EXISTING WALL CONTROL SW350 WALL CONTROL BLK BLK BLK BLACK LOAD TRAVELER WIRES HOT BLK Off On Up Down Lights Fan Sleep Off On Up Down Lights Fan Sleep 3 WAY WIRING DIAGRAM RETROFIT Figure 13 Do not connect any neutral white ...

Page 8: ...e SW375 Receiver If any changes have been made to the fan or light functions using the SW350 Wall Control those changes are not indicated on the remote LCD display When the SR330 Remote Control buttons are pressed the fan and light functions change to the LCD display settings Off On Up Down Lights Fan Sleep YELLOW WIRE TO YELLOW WIRE Built in Up Light Only BLUE WIRE TO BLUE WIRE SW375 RECEIVER WIR...

Page 9: ...he Up Down arrow buttons without disabling the Sleep function The fan will continue to decrease by one speed every 60 minutes until the fan is on low speed NOTE The Code Learning Procedure must be performed before the wall control will operate the fan or light NOTE An audible tone will be heard from the receiver whenever any of the fan light or any other function buttons are pressed A LIGHT Functi...

Page 10: ...ed as follows The uplight and downlight can be operated independently Press the Select button to change between downlight uplight fan operation When the downlight symbol glows on the LCD panel you have control of the down light When the uplight symbol glows on the LCD panel you have control of the uplight NOTE The Light On Off button features a soft on soft off feature that ramps the downlight dow...

Page 11: ...t setting The Sleep icon will be seen on the LCD panel indicating Sleep mode If the fan is already on then it will decrease from its current setting If the fan is off it will start from fan setting 3 medium and decrease from there Once the Sleep function is activated the fan speed can be increased or lowered using the Up Down Arrow buttons without disabling the Sleep function The fan will continue...

Page 12: ...amage in transit since we will not be responsible for any such damage What Is Not Covered This warranty also does not cover any defects malfunctions or failures caused by Repairs by persons not authorized by Emerson Electric Co Use of parts or accessories not authorized by Emerson Electric Co Mishandling improper installation modifications or damage to your remote control while in your possession ...

Reviews: