Quick Installation Guide
00825-0100-4420, Rev DA
July 2009
1420 Wireless Gateway
16
ATEX Directive (94/9/EC)
Emerson Process Management complies with the ATEX Directive.
Electro Magnetic Compatibility (EMC) (2004/108/EC)
Emerson Process Management complies with the EMC Directive.
Radio and Telecommunications Terminal Equipment Directive (R&TTE)(1999/5/EC)
Emerson Process Management complies with the R&TTE Directive
European Certification
N1 ATEX Type n
Certificate Number: Baseefa 07ATEX0056X
ATEX Marking: Ex II 3 G
Ex nA Nl IIC T4 (-40 °C < T
a
< 60 °C)
Special Conditions for Safe Use (X)
The surface resistivity of the antenna is greater than one gigaohm. To avoid
electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry
cloth.
The Apparatus is not capable of withstanding the 500V insulation test required by
Clause 9.4 of EN 60079-15: 2005. This must be taken into account when installing the
apparatus.
ND ATEX Dust
Certificate Number: Baseefa 07ATEX0057
EX tD A 22 IP66 T135 (-40 °C < T
a
< 60 °C)
Ex nA nL IIC T4 T4 (-40 °C < T
a
< 60 °C) II 3D
Vmax = 28V
N7 IECEx Type n
Certificate Number: IECEx BAS 07.0012X
Ex nC IIC T4 (-40 °C =< T
a
<=60 °C)
Rated Voltage: 28V
Special conditions for safe use (X)
The surface resistivity of the antenna is greater than one gigaohm. To avoid
electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry
cloth.
The Apparatus is not capable of withstanding the 500V insulation test required by
Clause 9.4 of EN 60079-15: 2005. This must be taken into account when installing the
apparatus.
NF IECEx Dust
Certification Number: IECEx BAS 07.0013
Ex tD A22 IP66 T135 (-40 °C < T
a
< 60 °C)
V
max
= 28V
Combinations of Certifcations
KD
Combination of N5, N6, and N1.
00825-0100-4420_Rev_DA.fm Page 16 Friday, July 17, 2009 10:15 AM