Functional Description
RTM-ATCA-F125 Installation and Use (6806800K30C
)
36
4.2.1
FRU Serial EEPROM
The RTM-ATCA-F125 provides a 128 Kb (16 K byte) I2C serial EEPROM. This is a 24LC128 type
device. The EEPROM resides at I2C address 0xA0.
This serial EEPROM is intended to hold FRU data and any additional parameters that are
required.
4.2.2
Temperature Sensors
The RTM-ATCA-F125 has provision for three temperature sensors that are located on the
primary side of the board close to the top, middle and bottom of the RTM. These sensors are
I2C-based LM75-type devices.
The over-temperature outputs from the three sensors are connected to the RTM FPGA to allow
an interrupt to the service processor to be generated in the event of an over-temperature
condition.
The I2C addresses for these devices are 0x90 (top), 0x91 (middle) and 0x92 (bottom).
4.2.3
LEDs
The RTM-ATCA-F125 provides four panel-visible LEDs that provide the standard ATCA
management LED functions:
z
RED - Out of Service
z
Green - In Service
Table 4-1 Temperature Sensor Thresholds
Sensor
Non-Critical Threshold / C Critical Threshold / C
Non-recoverable
Threshold / C
Upper
58
69
80
Middle
56
65
76
Lower
54
61
72
Summary of Contents for RTM-ATCA-F125
Page 6: ...RTM ATCA F125 Installation and Use 6806800K30C Contents 6 Contents Contents ...
Page 8: ...RTM ATCA F125 Installation and Use 6806800K30C 8 List of Tables ...
Page 10: ...RTM ATCA F125 Installation and Use 6806800K30C 10 List of Figures ...
Page 14: ...RTM ATCA F125 Installation and Use 6806800K30C About this Manual 14 About this Manual ...
Page 28: ...Hardware Preparation and Installation RTM ATCA F125 Installation and Use 6806800K30C 30 ...
Page 32: ...Controls LEDs and Connectors RTM ATCA F125 Installation and Use 6806800K30C 34 ...
Page 48: ...Related Documentation RTM ATCA F125 Installation and Use 6806800K30C 50 ...
Page 58: ...RTM ATCA F125 Installation and Use 6806800K30C Sicherheitshinweise 60 ...
Page 60: ...Index RTM ATCA F125 Installation and Use 6806800K30C 62 ...
Page 61: ......