205
Reference Manual
00809-0100-4021, Rev GC
Appendix A: Reference Data
April 2014
Figure A-1. HART / 4–20 mA Wiring Diagram
3144P Single-Sensor connections diagram
3144P Dual-Sensor connections diagram
(1) Transmitter must be configured for a 3-wire RTD in order to recognize an RTD with a compensation loop.
(2) Emerson Process Management provides 4-wire sensors for all single-element RTDs. You can use these RTDs in 3-wire configurations by leaving the unneeded leads
disconnected and insulated with electrical tape.
Figure A-2. F
OUNDATION
fieldbus Wiring Diagram
3144P Single-Sensor connections diagram
3144P Dual-Sensor connections diagram
(1) Transmitter must be configured for a 3-wire RTD in order to recognize an RTD with a compensation loop.
(2) Emerson Process Management provides 4-wire sensors for all single-element RTDs. You can use these RTDs in 3-wire configurations by leaving the unneeded leads
disconnected and insulated with electrical tape.
4-wire RTD
and Ohms
T/Cs and
Millivolts
RTD with Compensation
Loop
2-wire RTD
and Ohms
3-wire RTD
T/Hot Backup/Dual
Sensor with
2 RTDs
T/Hot Backup/Dual
Sensor with 2
Thermocouples
T/Hot Backup/Dual
Sensor with RTDs/
Thermocouples
T/Hot
Backup/Dual
Sensor with RTDs/
Thermocouples
T/Hot Backup/Dual
Sensor with 2 RTDs with
Compensation Loop
4-wire RTD
and Ohms
T/Cs and
Millivolts
RTD with Compensation
Loop
2-wire RTD
and Ohms
3-wire RTD
and Ohms
T/Hot Backup/Dual
Sensor with 2 RTDs
T/Hot Backup/Dual
Sensor with 2
Thermocouples
T/Hot Backup/Dual
Sensor with RTDs/
Thermocouples
T/Hot Backup/Dual
Sensor with RTDs/
Thermocouples
T/Hot Backup/Dual
Sensor with 2 RTDs with
Compensation Loop
Summary of Contents for Rosemount
Page 1: ...Reference Manual 00809 0100 4021 Rev GC April 2014 Rosemount 3144P Temperature Transmitter ...
Page 2: ......
Page 4: ...iv Reference Manual 00809 0100 4021 Rev GC Title Page April 2014 ...
Page 10: ...x Reference Manual 00809 0100 4021 Rev GC Table of Contents April 2014 Table of Contents ...
Page 38: ...28 Reference Manual 00809 0100 4021 Rev GC Section 2 Installation April 2014 Installation ...
Page 188: ...178 Reference Manual 00809 0100 4021 Rev GC Section 5 Maintenance April 2014 Maintenance ...
Page 250: ...Index 244 Reference Manual 00809 0100 4021 Rev GC Index April 2014 Index ...
Page 251: ......