Emerson Rosemount ET310C Quick Start Manual Download Page 1

Quick Start Guide

MS-00825-0100-4224, Rev AA

September 2022

Rosemount Wireless Permasense
ET310C Corrosion Transmitter 

Summary of Contents for Rosemount ET310C

Page 1: ...Quick Start Guide MS 00825 0100 4224 Rev AA September 2022 Rosemount Wireless Permasense ET310C Corrosion Transmitter ...

Page 2: ... resistivity greater than one gigaohm Care must be taken during transportation to and from the point of installation to prevent electrostatic charge build up NOTICE Shipping considerations for wireless products The unit was shipped to you without the power module installed Remove the power module prior to any re shipping Each device contains two D size primary lithium thionyl chloride battery cell...

Page 3: ...Contents Product overview 5 Wireless considerations 8 Physical installation 9 Commissioning the sensor 14 Maintenance 18 Product certification 19 September 2022 Quick Start Guide Quick Start Guide 3 ...

Page 4: ...Quick Start Guide September 2022 4 Emerson com Rosemount ...

Page 5: ...1 Product overview Figure 1 1 E310C Sensor A Antenna B Power Module C Head D Lanyard Hole E Strap Slot F Foot G Shoe September 2022 Quick Start Guide Quick Start Guide 5 ...

Page 6: ...d kit 6 6 ft 2 m 316 stainless steel lanyard with looped end and cable lock 3 3 ft 1 m strap for pipes up to 8 in diameter BP20E power module A silicone rubber shoe for installations on pipes size NPS 2 or 3 A silicone rubber shoe for installations on pipes size 4 in to 8 in Quick Start Guide September 2022 6 Emerson com Rosemount ...

Page 7: ... application software CC21 interface CAUTION The tablet PC is not intrinsically safe A site specific permit may be required for its use 1 3 Required tooling Tooling is supplied in the IK220 installation kit Strap tightening tool HCL SM FT 2000 2 5 mm hex key for power module retaining bolts September 2022 Quick Start Guide Quick Start Guide 7 ...

Page 8: ...ess devices should be powered up in order of proximity from the Gateway beginning with the closest device then working outward from the Gateway This results in a simpler and faster network formation Enable Active Advertising on the Gateway to ensure new devices are able to join the network faster For more information see the Emerson Wireless 1410S Gateway Quick Start Guide September 2022 8 Emerson...

Page 9: ...e insulation Insulation materials can be installed around the sensor as desired and according to local procedures 3 Clean the area where the sensor will touch the pipe to remove any particles that might keep the transducer away from the pipe surface or damage the face of the transducer A permanent marker may be used to show exactly where each sensor is to be placed on the pipe 4 A key pipe diamete...

Page 10: ...ensor Procedure 1 Remove the strap from the packaging 2 Remove the protective cap from the sensor CAUTION Once the protective cap is removed the strong magnetic field at the end of the sensor can suddenly attract other objects such as tools Figure 3 1 Sensor with Protective Cap Quick Start Guide September 2022 10 Emerson com Rosemount ...

Page 11: ...g do not use the sensor 4 Carefully place the sensor in the required location on the pipe NOTICE The magnets used in the sensors have a high pull force To avoid damage and to get the precise location for each sensor initially place the sensor at an angle to the pipe and then gently lower the shoe onto the pipe Tip One person should hold the sensor until the strap is installed 5 Slide the strap thr...

Page 12: ...the strap tightening tool Figure 3 3 Cutting away excess strap 8 Prepare the lanyard kit and decide how it will be positioned Wrap the lanyard around the circumference of the pipe The 7 ft 2 m length will accommodate a maximum diameter of 24 in 610 mm When it is not possible to wrap the lanyard around a pipe find an alternative attachment point for the lanyard 9 Thread the bare end of the wire thr...

Page 13: ...eleased from the cable lock using the release key A Release key 11 Feed the bare end through the lanyard hole in each sensor and then into the return hole of the gripple 12 To complete sensor installation first complete the commissioning task and then go to Completing sensor installation September 2022 Quick Start Guide Quick Start Guide 13 ...

Page 14: ...wer module The CC21 USB connector is plugged in to the tablet PC see Note All the sensors connected to the network and Gateway must have the same network ID and Join Key Procedure 1 Power up the rugged tablet PC and connect the CC21 commissioning interface to the tablet PC USB port Figure 4 1 Commissioning Kit A Tablet PC B CC21 interface C USB cable D Rosemount Wireless Permasense Sensor 2 Double...

Page 15: ...y is visible in the Network Discovery panel Note Joining the device to the network could take several minutes Figure 4 2 Install Tool 4 1 Completing sensor installation Complete the following steps in the installation application software on the installation tab Procedure 1 Press the Start button and wait for an ultrasonic waveform to download from the sensor Waveforms are automatically downloaded...

Page 16: ...or to a slightly different position 3 Verify that the measured thickness displayed is in line with expectations 4 Tighten the strap using the tensioning tool provided so that the rubber shoe is compressed slightly and the sensor is held in place securely Note Overtightening the strap will deform the shoe and could damage the sensor 5 Wait for a new waveform to display and check the ultrasonic wave...

Page 17: ...y Provisioned 8 Remove the CC21 and fit the power module tightening the two power module retaining bolts When the power module is fitted the sensor restarts and tries to join the WirelessHART gateway In a large network of 100 sensors this join can often take 2 hours and sometimes up to 6 hours 9 Sensor installation is complete September 2022 Quick Start Guide Quick Start Guide 17 ...

Page 18: ... sensor is a sealed unit with no user serviceable parts Reference the Rosemount BP20E Power Module for Wireless Corrosion Transmitter Quick Start Guide if the power module requires changing Quick Start Guide September 2022 18 Emerson com Rosemount ...

Page 19: ...CC Rules Operation is subject to the following conditions This device may not cause harmful interference This device must accept any interference received including interference that may cause undesired operation This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons ISED notice This device contains licence exempt transmitter s receiver s that compl...

Page 20: ...one marked equipment in Divisions The markings must be suitable for the area classification gas and temperature class This information is clearly defined in the respective codes 6 6 Dangerous goods regulation The magnets in the sensor and magnetic fixture are shielded for transportation and meet the IATA Dangerous Goods Regulations for magnetic fields The sensors are safe for air transportation 6 ...

Page 21: ...n hazard and must not be rubbed or cleaned with a dry cloth 6 10 International 6 10 1 I7 IECEx Intrinsic Safety IS Certificate IECEx BAS 17 0047X Standards IEC 60079 0 2017 Edition 7 0 IEC 60079 11 2011 Edition 6 0 Markings Ex ia IIC T4 T2 Ga Tamb 50 C to 75 C IP67 Special Condition for Safe Use X 1 The plastic mounting foot may present a potential electrostatic ignition risk and must not the rubb...

Page 22: ...y Certificate RU C GB АЖ58 В 01828 21 Standards ТР ТС 0 12 2011 Markings 0Ex ia IIC T4 T2 Ga X Special Condition for Safe Use X See certificate for specific conditions of safe use 6 13 Brazil 6 13 1 I2 INMETRO Intrinsic Safety IS Certificate UL BR 21 1297X Standards ABNT NBR IEC 60079 0 2020 ABNT NBR IEC 60079 11 2013 Markings Ex ia IIC T4 T2 Ga 50 C Tamb 75 C Special Conditions for Safe Use X See...

Page 23: ...6 14 EU Declaration of Conformity Figure 6 1 Declaration of Conformity September 2022 Quick Start Guide Quick Start Guide 23 ...

Page 24: ...6 15 China RoHS Quick Start Guide September 2022 24 Emerson com Rosemount ...

Page 25: ...September 2022 Quick Start Guide Quick Start Guide 25 ...

Page 26: ...Quick Start Guide September 2022 26 Emerson com Rosemount ...

Page 27: ...September 2022 Quick Start Guide Quick Start Guide 27 ...

Page 28: ...ore information Emerson com 2022 Emerson All rights reserved Emerson Terms and Conditions of Sale are available upon request The Emerson logo is a trademark and service mark of Emerson Electric Co Rosemount is a mark of one of the Emerson family of companies All other marks are the property of their respective owners ...