Quick Installation Guide

00825-0100-4377, Rev BA

October 2010

6

Rosemount 752

P

RODUCT

 C

ERTIFICATIONS

Approved Manufacturing Locations

Rosemount Inc. — Chanhassen, Minnesota  USA

European Directive Information

The EC declaration of conformity for all applicable European directives for this product can 
be found on the Rosemount website at www.rosemount.com. A hard copy may be obtained 
by contacting our local sales office.

Electro Magnetic Compatibility (EMC)

EN 61326:2006

ATEX Directive (94/9/EC)

Emerson Process Management complies with the ATEX Directive.

Hazardous Locations Certifications

North American Certifications

Factory Mutual (FM) Approvals
E5

Explosion-proof for Class I, Division 1, Groups B, C, and D; 

Dust Ignition-proof for Class II and Class III, Division 1, Groups E, F, and G hazardous 

locations; 

T5 (-50 °C to 80 °C) conduit seal not required

Enclosure Type 4X

I5/IE

Intrinsically Safe for use in Class I, Division 1, 

Groups A, B, C, and D; Class II, Division 1, 

Groups E, F, and G; Class III, Division 1; Class I, Zone 0

AEx ia IIC T4; when connected in accordance with Rosemount drawing 00752-1010; 

Temperature Code T4 (T

a

 = 60 °C); 

Non-incendive for Class I, Division 2, Groups A, B, C, and D. 

Enclosure Type 4X 

For entity parameters see control drawing 00752-1010. 

Canadian Standards Association (CSA) Approvals
E6

Explosion-proof for Class I, Division 1, Groups B, C, D; 

Dust Ignition-proof for Class II, Groups E, F, G;

Dust Ignition-proof for Class III

Temperature Code T5, (T

a

 = 80 °C)

Suitable for Class I, Division 2, Groups A, B, C,D; 

Temperature Code T3C (T

a

 = 40° C)

Enclosure Type 4X

I6/IF

Intrinsically Safe for Class I, Division 1, Groups A, B, C, D when installed in 

accordance with Rosemount drawing 00752-1020.

Temperature Code T3C (T

a

 = 40° C)

Enclosure Type 4X

4377_rev BA.fm  Page 6  Wednesday, October 13, 2010  2:38 PM

Summary of Contents for Rosemount 752

Page 1: ... Quick Installation Guide 00825 0100 4377 Rev BA October 2010 Rosemount 752 Rosemount 752 Remote Indicator with FOUNDATION fieldbus Protocol Step 1 Wiring Connection Step 2 Configure the Transducer Block Product Certification Start End ...

Page 2: ...his manual is also available electronically on www rosemount com WARNING Explosions could result in death or serious injury Installation of this indicator in an explosive environment must be in accordance with the appropriate local national and international standards codes and practices Please review the approvals section of the Rosemount 752 reference manual for any restrictions associated with ...

Page 3: ...r terminals are rated to 32 Vdc Figure 1 Fieldbus terminal block Electrical Considerations Proper electrical installation is necessary to prevent errors due to improper grounding and electrical noise Shielded twisted pair cable should be used for best results in electrically noisy environments Cable Type A is recommended by FOUNDATION fieldbus Power Supply The indicator requires between 9 and 32 V...

Page 4: ... most effective indicator case grounding method is a direct connection to earth ground with minimal impedance Methods for grounding the indicator case include Internal Ground Connection The Internal Ground Connection screw is inside the terminal side of the electronics housing The screw is identified by a ground symbol and is standard on the 752 Remote Indicators External Ground Assembly Ground sc...

Page 5: ...meter to be displayed The default function block tags from the factory are PID_1200 ISEL_1300 CHAR_1400 ARITH_1500 INTEG_1600 BLK_TYPE_ 1 Enter the Block Type of the function block that contains the parameter to be displayed e g ISEL PID etc PARAM_INDEX_ 1 Choose the parameter to be displayed CUSTOM_TAG_ 1 The CUSTOM_TAG_ is an optional user specified tag identifier that can be configured to be di...

Page 6: ...on 1 Groups E F and G hazardous locations T5 50 C to 80 C conduit seal not required Enclosure Type 4X I5 IE Intrinsically Safe for use in Class I Division 1 Groups A B C and D Class II Division 1 Groups E F and G Class III Division 1 Class I Zone 0 AEx ia IIC T4 when connected in accordance with Rosemount drawing 00752 1010 Temperature Code T4 Ta 60 C Non incendive for Class I Division 2 Groups A ...

Page 7: ...he apparatus is not capable of withstanding the 500V test as defined in Clause 6 3 12 of EN 60079 11 2007 This must be taken into account during installation 2 The enclosure may be aluminium protected against low levels of impact by a coating of epoxy polyester or polyurethane paint The risk of high levels of impact must be considered in any installation and protected accordingly N1 ATEX Type n Ce...

Page 8: ...ter or polyurethane paint The risk of high levels of impact must be considered in any installation and protected accordingly N7 IECEx Type n Certificate Number IECEx BAS 04 0030X Ex nA II T5 40 C Ta 70 C Special Condition for Safe Use X 1 When fitted with the transient option the apparatus is not capable of withstanding the 500 V electrical strength test as defined in Clause 8 of IEC 60079 15 1987...

Page 9: ...Quick Installation Guide 00825 0100 4377 Rev BA October 2010 9 Rosemount 752 Figure 3 752 EC Declaration of Conformity ...

Page 10: ...Quick Installation Guide 00825 0100 4377 Rev BA October 2010 10 Rosemount 752 ...

Page 11: ...Quick Installation Guide 00825 0100 4377 Rev BA October 2010 11 Rosemount 752 ...

Page 12: ...Quick Installation Guide 00825 0100 4377 Rev BA October 2010 12 Rosemount 752 ...

Reviews: