Emerson Rosemount 708 Quick Installation Manual Download Page 1

www.rosemount.com

Quick Installation Guide

00825-0200-4708, Rev AD
April 2012

Rosemount 708

Wireless Considerations

Step 1: Physical Installation

Step 2: Device Network Configuration

Step 3: Verify Operation

Product Certifications

EC Declaration of Conformity

Start

End

Rosemount 708 Wireless Acoustic Transmitter

Summary of Contents for Rosemount 708

Page 1: ...4708 Rev AD April 2012 Rosemount 708 Wireless Considerations Step 1 Physical Installation Step 2 Device Network Configuration Step 3 Verify Operation Product Certifications EC Declaration of Conformity Start End Rosemount 708 Wireless Acoustic Transmitter ...

Page 2: ...s device must be installed to ensure a minimum antenna separation distance of 8 in 20 cm from all persons The Power Module may be replaced in a hazardous area The Power Module has surface resistivity greater than one gigaohm and must be properly installed in the wireless device enclosure Care must be taken during transportation to and from the point of installation to prevent a potential electrost...

Page 3: ...on of Power Module in device Unscrew cap for access to Power Module 2 Waveguide Location of the acoustic and temperature sensors 3 Electronics cover The cover is sealed and cannot be removed 4 Stainless steel mounting bands Used to connect the acoustic transmitter to the piping 5 Pipe The acoustic transmitter is installed directly to the pipe 1 2 3 4 1 5 ...

Page 4: ...veguide horizontal and the Power Module closest to the ground as shown in Figure 1 Good connectivity can also be achieved in other orientations The antenna should also be approximately 3 ft 1 m from any large structure building or conductive surface to allow for clear communication to other devices Figure 1 Antenna Position Field Communicator Connections The Power Module needs to be installed in t...

Page 5: ...n should be free of foreign matter and corrosion to ensure good contact between the piping and the waveguide 3 Tighten each clamp to 90 in lb 10 2 N m Trim the excess clamp band material to prevent unwanted acoustic noise 4 If commissioning the device install the green Power Module see Figure 5 5 Ensure that the Power Module cover is fully tightened to prevent moisture ingress The lip of the polym...

Page 6: ...uide must be in direct contact with the pipe 3 Insulate process piping to minimize ambient temperature effects see Figure 6 Insulation thickness over the top of the waveguide foot should not exceed 1 in 2 54 cm 4 For best results mount the transmitter within 6 in 15 24 cm of the equipment to be monitored 5 The stainless steel mounting bands could be affected by stress corrosion and potentially fai...

Page 7: ...network If the network ID and join key are not the same as the Gateway the acoustic transmitter will not communicate with the network The Network ID and Join Key may be obtained from the Smart Wireless Gateway on the Setup Network Settings page on the web server shown in Figure 7 Figure 7 Gateway Network Settings AMS Right click on the acoustic transmitter and select Configure When the menu opens ...

Page 8: ...o join the network Field Communicator For HART Wireless transmitter communication a 708 DD is required To obtain the latest DD visit the Emerson Process Management Easy Upgrade site at http www2 emersonprocess com en US documentation deviceinstallkits The communication status may be verified in the wireless device using the following Fast Key sequence Smart Wireless Gateway Using the Smart Wireles...

Page 9: ...nual on the CD for more information Troubleshooting If the device is not joined to the network after power up verify the correct configuration of the Network ID and Join Key and that Active Advertising has been enabled on the Smart Wireless Gateway The Network ID and Join Key in the device must match the Network ID and Join Key of the Gateway The Network ID and Join Key may be obtained from the Ga...

Page 10: ...ntly used to interrogate and configure the device For additional information refer to the 708 product manual Document No 00809 0100 4708 Table 1 708 Fast Key Sequence Figure 11 Field Communicator Connections Function Key Sequence Menu Items Device Information 2 2 5 Tag Long Tag Descriptor Message Date Country SI Unit Control Guided Setup 2 1 Basic Setup Join Device to Network Configure Update Rate...

Page 11: ...s require certification to ensure that they adhere to regulations regarding the use of the RF spectrum Nearly every country requires this type of product certification Emerson is working with governmental agencies around the world to supply fully compliant products and remove the risk of violating country directives or laws governing wireless device usage FCC and IC This device complies with Part ...

Page 12: ...0 1998 FM3610 2010 ANSI NEMA 250 ANSI IEC60529 2004 CSA International I6 CSA Intrinsically Safe Certificate No 2439890 Applicable Standards CSA std C22 2 no 142 M1987 CSA Std C22 2 No 157 92 Intrinsically Safe for Class I Division 1 Groups A B C and D T3C 40 C Tamb 70 C Intrinsically safe when installed according to Rosemount Drawing 00708 1001 For use with SmartPower Solutions model number 701PGN...

Page 13: ...X Ex ia IIC T4 Ga Ta 40 C Tamb 70 C IP66 67 For use with SmartPower Solutions model number 701PGN green power module only Special Conditions for Safe Use X 1 The engineered polymer enclosure of the Rosemount 708 may constitute a potential electrostatic ignition risk and must not be rubbed or cleaned with a dry cloth Standards IEC60079 0 2007 10 IEC60079 11 2006 ...

Page 14: ...d Eden Prairie MN 55344 3695 Chanhassen MN 55317 9687 USA USA to which this declaration relates is in conformity with the provisions of the European Community Directives including the latest amendments as shown in the attached schedule Assumption of conformity is based on the application of the harmonized standards and when applicable or required a European Community notified body certification as...

Page 15: ... and Protocol Code 3 EN 61326 2 3 2006 R TTE Directive 1999 5 EC All Models with Output Code X and Operating Frequency and Protocol Code 3 EN 301 489 17 V2 1 1 2009 05 EN 61010 1 2001 Second Addition EN 300 328 V 1 7 1 2006 10 ATEX Directive 94 9 EC Model 708 Certificate Baseefa11ATEX0174X Intrinsically Safe Group II Category 1 G Ex ia IIC T4 Ga Ta 40 C to 70 C Harmonized Standards Used EN60079 0 ...

Page 16: ...Marking Page 3 of 3 ATEX Notified Bodies for EC Type Examination Certificate Baseefa Notified Body Number 1180 Rockhead Business Park Staden Lane Buxton Derbyshire SK17 9RZ United Kingdom ATEX Notified Body for Quality Assurance Baseefa Notified Body Number 1180 Rockhead Business Park Staden Lane Buxton Derbyshire SK17 9RZ United Kingdom ...

Reviews: