February 2019
18
Quick Start Guide
7.0 Product Certifications
Rev 1.0
7.1 European Directive Information
A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide.
The most recent revision of the EU Declaration of Conformity can be found at
7.2 Europe
I1
ATEX Intrinsic Safety
Certificate: Baseefa15ATEX0075X
Standards: EN60079-0:2012+A11:2013, EN60079-11:2012
Markings:
II 1 G Ex ia IIC T4 Ga (–40 °C
T
a
+85 °C)
Special Condition for Safe Use (X):
1. The Rosemount 520 Transmitter enclosure is manufactured of titanium and may
present a frictional ignition risk and must be protected from impact or abrasion if
located in a zone 0.
2. When a junction box is not used, the free ends of the cable must be afforded a degree of
protection of at least IP20.
3. The optional polyester junction box present a potential electrostatic ignition risk and
must not be rubbed or cleaned with a dry cloth.
Installation in Hazardous Locations
When installing the Rosemount 520 in hazardous areas, to reduce the risk of electrostatic
charges the resistance of the titanium transducer to earth should be less than10
9
Ω
.
7.3 International
I7
IECEx Intrinsic Safety
Certificate: IECEx BAS 15.0050X
Standards: IEC60079-0:2011, IEC60079-11:2011
Markings: Ex ia IIC T4 Ga (–40 °C
T
a
+85 °C)
Table 7. Input Parameters
Parameter
HART
Voltage U
i
30 V
Current I
i
200 mA
Power P
i
1.0 W
Capacitance C
i
42 nF
Inductance L
i
77
H
Table 8. Input Parameters
Parameter
HART
Voltage U
i
30 V
Current I
i
200 mA
Power P
i
1.0 W
Capacitance C
i
42 nF
Inductance L
i
77
H