Quick Start Guide
3.5 Flange with 1-in. ball valve mounting
1. Install a suitable flange connection to the tank wall.
2. Secure the provided flange and ball valve to the tank flange connection.
3. Secure the transmitter in the ball valve by use of the provided nut and gasket.
The recommended torque is 20 N-m.
Figure 5. Installation Drawing
A. Optional junction box
B. Refer to
E. Dead zone
F. Tank bottom
G. Vent pipe
H. Flange
I. 1-in. ball valve
J. 1-in. nipple pipe connector 1-to 1-in.
K. Refer to
L. Gasket
M. 1-in. nut
N. Transmitter
Table 2. Flange Size for Flange with 1-in Ball Valve
Standard
D (mm)
B (mm)
K (mm)
d x n (mm)
DN25 PN16
115
16
85
14 x 4
JIS25A—16K
125
14
90
19 x 4
1-in. ANSI/150
108
16
79
16 x 4
A
G
C
F
E
H
I
J
L
M N
64
315
D K
d
B