Figure 4-6. HART Communicator Menu Tree corresponding to Device Revision 2.
Online Menu
1 DEVICE SETUP
2 PV
3 AO
4 LRV
5 URV
1 Device
Information
3 Volume
Geometry
4 HART
5 Advanced
Service
1 Variable mapping
2 Level
3 Distance
4 Volume
5 Internal Temp
6 Interface Dist
7 Interface Level
8 Amplitude Peak 1
- Amplitude Peak 2
- Amplitude Peak 3
- Upper Prod Thickn
1 Process
Variables
2 Diag/Service
3 Basic Setup
4 Detailed Setup
5 Review
1 Measurem Units
1 Level Unit
2 Volume Unit
3 Temperature Unit
1 Distributor
2 Model
3 Dev Id
4 Tag
5 Descriptor
6 Message
7 Date
8 Write Protect
9 Revision #´s
1 Tank Type
2 Tank Diameter
3 Tank Height
1 Gain Control
2 Max Up Prod Tkn
3 Thresholds
4 Reset to Default
5 Calibration Offst
1 Flange Type
2 Flange Material
3 Probe
4 Barrier
- Construction Details
1 Entries Used
2 Max Entries
3 Lvl0
4 Vol0
5 Lvl1
6 Vol1
7 Lvl2
8 Vol2
9 Lvl3
Vol3
Lvl9
Vol9
1 Poll addr
2 Num req preamps
3 Burst mode
4 Burst option
1 Strap Table
2 Ver Cylinder
3 Hor Cylinder
4 Vert Bullet
5 Hor Bullet
6 Sphere
7 None
4 Strapping Table
1 Variable re-map
2 PV is
3 SV is
4 TV is
5 QV is
- Level
- Distance
- Volume
- Internal Temp
- Interface Dist
- Interface Level
- Amplitude Peak 1
- Amplitude Peak 2
- Amplitude Peak 3
- Upper Prod Thickn
1 Status Group 1
2 Status Group 2
To enable volume
calculations based on
a strapping table, the
“Strapping Table”
option must be
selected for tank type
2 Display
1 Universal rev
2 Fld dev rev
3 Software rev
1 Display variables
2 Display language
1 PV is
2 Apply values
3 Range values
4 AO Values
1 Status
2 Master Reset
3 Loop Test
4 D/A Trim
5 Scaled D/A Trim
6 PV AO
7 PV AO Alarm Type
1 Ref Height
2 Probe Length
3 Probe Type
4 Probe Angle
5 Show Lvl=0
1 Upper Null Zone
2 Vapor Dielectric
3 Product Dielectric
4 Measurement Mode
3 Misc. settings
2 Geometry/Probe
4 Analog output
5 Damping Value
Summary of Contents for Rosemount 3300 Series
Page 2: ......
Page 4: ......
Page 8: ...Reference Manual 00809 0100 4811 Rev CA February 2006 Rosemount 3300 Series TOC 4 ...
Page 12: ...Reference Manual 00809 0100 4811 Rev CA February 2006 Rosemount 3300 Series 1 4 ...
Page 24: ...Reference Manual 00809 0100 4811 Rev CA February 2006 Rosemount 3300 Series 2 12 ...
Page 104: ...Reference Manual 00809 0100 4811 Rev CA February 2006 Rosemount 3300 Series 6 24 ...
Page 128: ...Reference Manual 00809 0100 4811 Rev CA February 2006 Rosemount 3300 Series A 24 ...
Page 145: ......