When fully tightened, the bolts should extend through the top of the sensor
module housing.
3. If you have replaced the PTFE sensor module O-rings, re-tighten the flange bolts
after installation to compensate for cold flow of the O-rings.
3.6.2
Install Rosemount 306 integral manifold
The Rosemount 306 Manifold is for use only with in-line pressure transmitters such as the
Rosemount 3051T and 2051T.
Assemble the Rosemount 306 manifold to the Rosemount 3051T or 2051T In-Line
Transmitters with a thread sealant.
3.6.3
Install Rosemount 304 Conventional Manifold
Procedure
1. Align the Conventional Manifold with the transmitter flange. Use the four manifold
bolts for alignment.
2. Finger tighten the bolts; then tighten the bolts incrementally in a cross pattern to
final torque value.
When fully tightened, the bolts should extend through the top of the sensor
module housing.
3. Leak-check assembly to maximum pressure range of transmitter.
3.6.4
Manifold operation
WARNING
Improper installation or operation of manifolds may result in process leaks, which may
cause death or serious injury.
Always perform a zero trim on the transmitter/manifold assembly after installation to
eliminate any shift due to mounting effects. See
.
Coplanar transmitters
Operate three and five-valve manifolds
Performing zero trim at static line pressure
In normal operation, the two isolate (block) valves between the process ports and the
transmitter will be open, and the equalize valve will be closed.
Reference Manual
Hardware installation
00809-0100-4774
July 2020
Reference Manual
73
Summary of Contents for Rosemount 3051 CF Series
Page 4: ...4 ...
Page 56: ...Configuration Reference Manual July 2020 00809 0100 4774 56 Rosemount 3051 ...
Page 92: ...Electrical installation Reference Manual July 2020 00809 0100 4774 92 Rosemount 3051 ...
Page 102: ...Operation and maintenance Reference Manual July 2020 00809 0100 4774 102 Rosemount 3051 ...
Page 118: ...Troubleshooting Reference Manual July 2020 00809 0100 4774 118 Rosemount 3051 ...
Page 138: ...Reference data Reference Manual July 2020 00809 0100 4774 138 Rosemount 3051 ...
Page 145: ...Reference Manual 00809 0100 4774 July 2020 Reference Manual 145 ...