PENBERTHY 

MODEL CTE MIXER / HEATER

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

7 DISASSEMBLY - REASSEMBLY

WARNING

Do not proceed with removal of the CTE from 
connecting piping unless the CTE has been 
relieved of all pressure or vacuum, has been 
allowed to reach ambient temperature and has 
been drained or purged of all fluids. Failure to 
follow these instructions may cause a sudden 
release of liquid or steam resulting in severe 
personal injury or property damage.

8 DISPOSAL AT END OF USEFUL LIFE

Penberthy CTEs are used in a variety of fluid 
applications. By following the appropriate 
federal and industry regulations, the user 
must determine the extent of preparation 
and treatment the CTE must incur before its 
disposal. A Material Safety Data Sheet (MSDS) 
may be required before disposal services accept 
certain components.
Metal, glass and polymers should be recycled 
whenever possible. Refer to order and relevant 
data sheet for materials of construction.

9 TELEPHONE ASSISTANCE

If you are having difficulty with your CTE, 
contact your local Penberthy distributor. So that 
we may assist you more effectively, please have 
as much of the following information available 
as possible when you call:
- Model number
- Name of the company from whom you 

purchased the CTE

- Invoice number and date
- Process conditions (pressure, flow rates, tank 

shape, etc.)

- A brief description of the problem
- Troubleshooting procedures that failed

If attempts to solve your problem fail, you may 
request to return your CTE to the factory for 
intensive testing. You must obtain a Return 
Authorization (R.A.) number from Emerson 
before returning anything. Failure to do so will 
result in the unit being returned to you without 
being tested, freight collect. To obtain an R.A. 
number, the following information (in addition to 
that above) is needed:
- Reason for return
- Person to contact at your company
- 'Ship-to' address

There is a minimum charge for evaluation 
of non-warranty units. You will be contacted 
before any repairs are initiated should the cost 
exceed the minimum charge. If you return a 
unit under warranty, but it is not defective, the 
minimum charge will apply.

Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product. 
Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.

Penberthy is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co. Emerson Automation Solutions, 
Emerson and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their respective owners.

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be 
construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by 
our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without 
notice.

Emerson.com/FinalControl

Summary of Contents for PENBERTHY CTE

Page 1: ...ts products or from any other cause or for consequential damages It is expressly understood that Emerson is not responsible for damage or injury caused to other products buildings personnel or property by reason of the installation or use of its products This is Emerson s sole warranty and in lieu of all other warranties expressed or implied which are hereby excluded including in particular all wa...

Page 2: ...Maximum inlet pressure 160 psig 1100 kPaG Most efficient operation takes place when inlet pressure is within the range of 20 to 70 psig 140 to 480 kPaG Three gallons of tank contents can be mixed for every gallon of operating fluid For inlet pressures outside this range 2 6 gallons of tank contents can be mixed for every gallon of operating fluid 2 Heating see Table 2 Operation at steam pressures ...

Page 3: ...s it is recommended that multiple CTEs be used FIGURE 1 FIGURE 2 Discharge Inlet Spherical Body 4 2 Effect of related piping and precautions 1 For mixing a Operating liquid supply line pressure loss must be taken into account when applying CTEs b Supply line must be clean and should be provided with a strainer to prevent foreign materials from clogging the mixer c CTEs must be fully submerged to p...

Page 4: ...ions may cause a sudden release of liquid or steam resulting in severe personal injury or property damage 6 1 Preventative maintenance The user must create maintenance schedules safety manuals and inspection details for each specific installation of a CTE mixer heater On all installations the following items should be evaluated regularly by the user for purposes of maintenance 1 CTE s for corrosio...

Page 5: ...intensive testing You must obtain a Return Authorization R A number from Emerson before returning anything Failure to do so will result in the unit being returned to you without being tested freight collect To obtain an R A number the following information in addition to that above is needed Reason for return Person to contact at your company Ship to address There is a minimum charge for evaluatio...

Reviews: