3.3.2
Wire sensor
WARNING
Do not open enclosures in a classified area (Do not open when an explosive atmosphere
may be present). Ensure the power to the transmitter is switched off before connecting
sensor wires.
Avoid touching electronic components, as they are susceptible to electrostatic discharge
(ESD). Refer to
Electrostatic sensitive device (ESD)
Connect sensor wires to the sensor terminals in the applicable transmitter. Refer to the
for sensor terminal definitions.
Table 3-1: Sensor Wires and Millennium II Series Terminal Definitions
Sensor terminals
Sensorwir
e
White
Red
Blue
Black
Green
Marked
+Vdc
Sig A
Sig B
COM
Function
10.5 -
32Vdc
A
B
Common/
supply
ground
Earth
ground
Note
When separating sensor from transmitter using Net Safety separation kit, refer to
purpose Junction Box Manual (MAN-0081)
for terminal designations. Always ensure that
the transmitter is supplying the required voltage across sensor power terminals inside
junction box. Refer to table above for sensor voltage requirements.
3.3.3
Installation checklist
Review the following checklist prior to turning the power on to the transmitter after
completing installation.
•
Ensure transmitter and sensor are properly and firmly mounted.
•
Ensure that stopping plug is tightened to unused conduit entry.
•
Ensure transmitter and sensor are not being obstructed; transmitter and sensor are
accessible and target gas is not inhibited from reaching sensor.
•
Ensure adherence to applicable local guidelines and requirements on wiring and
sealing of equipment in hazardous and non-hazardous areas.
•
Ensure that proper shielding and grounding practices are adhered to, and local codes
are being followed.
•
Check system operational voltage and conditions, ensuring that they are within the
applicable specifications of the transmitter and sensor.
•
Check wiring at all termination and junction points: transmitter, junction box, and
power supply.
Safety Manual
Installation
00809-0100-4310
May 2021
Net Safety SC310
15
Summary of Contents for Net Safety Millennium II SC310
Page 1: ...Safety Manual 00809 0100 4310 Rev AA May 2021 Millennium II SC310 Combustible Gas Sensor ...
Page 4: ...4 ...
Page 8: ...Introduction Safety Manual May 2021 00809 0100 4310 8 Emerson com Rosemount ...
Page 12: ...Plan Safety Manual May 2021 00809 0100 4310 12 Emerson com Rosemount ...
Page 16: ...Installation Safety Manual May 2021 00809 0100 4310 16 Emerson com Rosemount ...
Page 20: ...Output Safety Manual May 2021 00809 0100 4310 20 Emerson com Rosemount ...
Page 32: ...Maintaining Safety Manual May 2021 00809 0100 4310 32 Emerson com Rosemount ...
Page 36: ...Resistance table Safety Manual May 2021 00809 0100 4310 36 Emerson com Rosemount ...
Page 39: ...Safety Manual 00809 0100 4310 May 2021 Net Safety SC310 39 ...