29
Reference Manual
24625020, Rev AA
Installing the Electronics Control Unit
March 2017
Installing the Electronics Control Unit
Figure 3-7. Fitting 10/18/30 m Electrode Cable to 8-way Connector (PL205 and PL405)
A. Termination screws are on this side.
B. Connector on electrode cable.
C. Connector on Hydratect 2462 front panel printed circuit board: PL205 (Channel 1) and PL405 (Channel 2).
Figure 3-8. Fitting 3m Electrode Cable to 8-way Connector (PL205 and PL405)
A. Termination screws are on this side.
B. Connector on electrode cable.
C. Connector on Hydratect 2462 front panel printed circuit board: PL205 (Channel 1) and PL405 (Channel 2).
Red
Red
Black
Black
B
C
A
1
2
3
4
5
6
7
8
Red
White
Blue
Black
B
C
A
1
2
3
4
5
6
7
8