1
Planning
1.1
Installation checklist
□
Make sure that the hazardous area specified on the approval tag is suitable for the
environment in which the meter will be installed.
□
Verify that the local ambient and process temperatures are within the limits of the
meter.
□
If your sensor has an integral transmitter, no wiring is required between the sensor and
transmitter. Follow the wiring instructions in the transmitter installation manual for
signal and power wiring.
□
If your transmitter has remote-mounted electronics, follow the instructions in this
manual for wiring between the sensor and the transmitter, and then follow the
instructions in the transmitter installation manual for power and signal wiring.
Table 1-1: Maximum cable lengths
Cable type
To transmitter
Maximum length
Micro Motion 4-wire
All 4-wire MVD transmitters
—
1,000 ft (305 m) without
Ex-approval
—
500 ft (152 m) with IIC
rated sensors
—
1,000 ft (305 m) with IIB
rated sensors
Table 1-2: Maximum lengths for user-supplied 4-wire cable
Wire function
Wire size
Maximum length
Power (VDC)
22 AWG (0.326 mm
²
)
300 ft (91 m)
20 AWG (0.518 mm
²
)
500NaN ft (NaN m)
18 AWG (0.823 mm
²
)
1,000 ft (305 m)
Signal (RS-485)
22 AWG (0.326 mm
²
) or larger 1,000 ft (305 m)
□
For optimal performance, install the sensor in the preferred orientation. The sensor will
work in any orientation as long as the flow tubes remain full of process fluid.
Table 1-3: Preferred sensor orientation
Liquids
Installation Manual
Planning
20002346
January 2019
Installation Manual
5
Summary of Contents for Micro Motion H Series
Page 4: ...Contents Installation Manual January 2019 20002346 4 Micro Motion H Series ...
Page 12: ...Mounting Installation Manual January 2019 20002346 12 Micro Motion H Series ...
Page 20: ...Grounding Installation Manual January 2019 20002346 20 Micro Motion H Series ...
Page 23: ...Installation Manual 20002346 January 2019 Installation Manual 23 ...