This parameter defines the rate at which Easy Mode cyclic data will be transmitted in milliseconds.
A value of zero disables the transmission of data.
This parameter is reserved to select the profile of predefined output mappings for the transmit link.
If this parameter is set to a non-zero value then
Tx Link Source Parameter
(
S.10.012
,
S.10.022
or
S.10.032
) and
Tx Link Parameter Count
(
S.10.013
,
S.10.023
or
S.10.033
) will become read-only
with value of 0.
This parameter is used to set the link number for the transmit link. This number should be unique
for each transmit link.
S.10.004
Message Rate
Minimum
0
Maximum
100
Default
0
Units
ms
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, BU
S.10.010
Tx1 Link Profile
S.10.020
Tx2 Link Profile
S.10.030
Tx3 Link Profile
Minimum
0
Maximum
0
Default
0
Units
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, BU
S.10.011
Tx1 Link Number
S.10.021
Tx2 Link Number
S.10.031
Tx3 Link Number
Minimum
0
Maximum
255
Default
0
Units
Type
8 Bit User Save
Update Rate
Read on reset
Display Format
None
Decimal Places
0
Coding
RW, BU