Repair Parts Listing

Part Numbers

Key

Model No.

Model No.

No.

Description

CF690CK00

CF690ORB00

*

Hanger Ball Assembly,

761655-23

761655-32

Consisting of:

1

Hanger Bracket

2

Hanger Ball

3

Downrod

*

Parts Bag Containing:

763234

763234-1

4

Wire Connector (3)

5

Threaded Stud (2)

7

Lockwasher (2)

8

Knurled Knob (2)

10

Pin, Clevis

11

Clip, Hairpin

15

Wood Pendant

16

Coupling

17

Screw, Blade M5 x 6 

Washer Head (16)

20

Screw, Flange M6 x 14

with Lockwasher (1)

6

Ceiling Canopy

761504-19

761504-20

9

Coupling Cover

762463-2

762463-16

12

Bracket Switch Housing Assembly

with Mounting Screws and

763237

763237-1

Rubber Cover

13

Switch Housing Assembly

763241

763241-1

14

Wiring Harness

762993-2

762993-2

18

Blade (set of 5)

762947-1

762947-2

19

Flange (set of 5)

763173-CK

763173-ORB

Owner's Manual

BP7331

BP7331

Summary of Contents for MARIOL PORTICO CF690CK00

Page 1: ...duct to an authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Cover...

Page 2: ...Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an 8 foot ceiling 5 The fan must be mounted with the fan blad...

Page 3: ...om the loose parts bag in a small container to keep them from being lost If any parts are missing contact your local retailer or catalog outlet for replacement before proceeding 2 Remove the fan motor assembly from the protective plastic bag Place the fan assembly into the upper foam pad with the top of the motor facing up The upper foam pad serves as a holder for the fan during the first stages o...

Page 4: ... cover and the coupling cover are both oriented correctly Figure 3 5 Reinstall the hanger ball Figure 4 on the downrod as follows Route the three 80 motor leads through the hanger ball Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball Pull the hanger ball up tight against the pin and securely tighten t...

Page 5: ...ening the screws Make sure all the flanges are properly engaged and then tighten the flange screws If one of the flanges does not seat properly on the motor hub loosen the adjacent flange screws re engage and reseat the flanges then tighten the screws again 11 Remove and retain one of the three serrated head screws from the adaptor plate Figure 6 Loosen the other two serrated head screws three or ...

Page 6: ... bracket WARNING AT LEAST 7 CEILING FLOOR Figure 10 The fan must be hung with at least 7 of clearance from floor to blades Figure 10 WARNING Hanger bracket must seat firmly against outlet box If the outlet box is recessed remove wall board until bracket contacts box If bracket and or outlet box are not securely attached the fan could wobble or fall WARNING 1 Securely attach the hanger bracket to t...

Page 7: ...ible electrical shock be sure electricity is turned off at the main fuse box before wiring NOTE If you are not sure if the outlet box is ground ed contact a licensed electrician for advice as it must be grounded for safe operation WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson E...

Page 8: ... proper installation and use of the ceil ing fan Here are a few tips to ensure quality and product performance Choosing the Appropriate Mounting Location Ceiling fans should be installed or mounted in the middle of the room and at least 7 feet above the floor and 18 inches from the walls If ceiling height allows install the fan 8 9 feet above the floor for optimal air flow Consult your Emerson Ret...

Page 9: ...tach the fan blade flanges to the motor are tight 4 Fan blade flanges not seated properly 4 Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor If flanges are seated incorrectly loosen the flange screws and retighten according to the procedure in the section on How to Put Your Ceiling Fan Together 5 Hanger bracket and or ceiling outlet box is not 5 Tighten ...

Page 10: ...R REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 6 4 9 8 5 7 11 10 19 18 13 15 16 12 17 1 2 3 20 14 ...

Page 11: ... Knob 2 10 Pin Clevis 11 Clip Hairpin 15 Wood Pendant 16 Coupling 17 Screw Blade M5 x 6 Washer Head 16 20 Screw Flange M6 x 14 with Lockwasher 1 6 Ceiling Canopy 761504 19 761504 20 9 Coupling Cover 762463 2 762463 16 12 Bracket Switch Housing Assembly with Mounting Screws and 763237 763237 1 Rubber Cover 13 Switch Housing Assembly 763241 763241 1 14 Wiring Harness 762993 2 762993 2 18 Blade set o...

Page 12: ...Part No F40BP73310000 Printed in China 10 06 Form No BP7331 Air Comfort Products DIVISION OF EMERSON ELECTRIC CO 8100 W Florissant St Louis MO 63136 ...