Appendix C
Data types
Topics covered in this appendix:
•
•
•
•
Non-Vibration unit analysis types
•
C.1
Gross Scan analysis
Includes Overall RMS Level, Sensor DC Bias, Gap, DC, or AC Process signals.
Note
Some DC Process Inputs could provide pk, pk-pk, or other Measurement Units.
Gross Scan parameters
All Gross Scan inputs must be DC in nature. Any Gross Scan input of a dynamic nature must
be fed through the RMS/DC converter path. It is not technically valid to convert RMS values
from an RMS/DC converter to pk or pk-pk Measurement Units unless the input is sinusoidal
in nature. However, the CSI 2600 allows this. RMS values are multiplied by 1.414 or 2.828
to convert from RMS to pk and pk-pk, respectively.
C.1.1
Gross Scan units conversion
Gross Scan units conversion
Table C-1:
Input
Type
Input Unit
HW Int.
RMS/DC
Meas. Unit
Disp. Unit
DC
V / E.U.
no
no
DC
E.U.
AC
V / E.U.
no
yes
RMS
E.U.
ACCEL
V / 32.2 ft/s
V / 32.2 ft/s
V / 9.81 m/s
V / 9.81 m/s
no
yes
no
yes
yes
yes
yes
yes
RMS
RMS
RMS
RMS
g
in./s
g
mm/s
Data types
MHM-97453, Rev 1
87
Summary of Contents for Machinery Health Expert CSI 2600
Page 1: ...User Guide MHM 97453 Rev 1 April 2014 CSI 2600 Machinery Health Expert User Guide ...
Page 8: ...CSI 2600 back view Figure 2 2 Introduction to the CSI 2600 4 MHM 97453 Rev 1 ...
Page 12: ...Introduction to the CSI 2600 8 MHM 97453 Rev 1 ...
Page 26: ...Getting started 22 MHM 97453 Rev 1 ...
Page 64: ...Software configuration 60 MHM 97453 Rev 1 ...
Page 96: ...Data types 92 MHM 97453 Rev 1 ...
Page 100: ...D 2 Internal wiring diagram for the CSI 2600 ...
Page 106: ...Troubleshooting 102 MHM 97453 Rev 1 ...
Page 109: ...Index MHM 97453 Rev 1 105 ...