Operator Control and Display Panel
63
Table 19
Descriptions of UPS menus and data window items
Menu Type
Item Type
Explanation
Mains
(input)
L-N current (A)
Phase current
Frequency (Hz)
Input frequency
L-L voltage (v
Line-line voltage
Power factor
Power factor
TX Input
L-L voltage (V)
Line-line voltage
Bypass
Frequency (Hz)
Bypass frequency
L-L voltage (A)
Line-line voltage
Output
L-N current (A)
Phase current
Frequency (Hz)
Output frequency
L-L voltage (V)
Line-line voltage
Power factor
Power factor
TX Output
L-L voltage (V)
Line-line voltage
Load
Sout (kVA)
Sout: Apparent power
Pout (kW)
Pout: Active power
Qout (kVAR)
Qout: Reactive power
Loadlevel %
The percent of the UPS rating load
Crest factor
Output current Crest Factor
System
Sout (kVA)
Sout: Apparent power
Pout (kW)
Pout: Active power
Qout (kVAR)
Qout: Reactive power
Single unit, no parallel data
When configured as a single unit, UPS has only native load, no system load.
Battery
Battery voltage (V)
Battery bus voltage
Battery current (A)
Battery bus current
Battery temperature (°C)
Internal battery temperature °C
Remain Time Min.
Battery run time remaining
Battery boost charging
Battery is boost charging
Battery float charging
Battery is float charging
Battery disconnected
Battery is not connected
Records
(History Log)
Displays all records in the history log
Language
(choices for text displayed)
User may select any of 12 languages for LCD text.
Settings
Display contrast
Adjust the LCD contrast
Date format set
Choose the format for date display: M/D/Y, D/M/Y, M/D/Y, Y/M/D
Date & time
Set the date and time
Comm1 baud rate
Communication baud rate setting for Liebert IntelliSlot 1
Comm2 baud rate
Communication baud rate setting for Liebert IntelliSlot 2
Comm3 baud rate
Communication baud rate setting for Liebert IntelliSlot 3
Communication address
This setting is applicable to RS485 communication mode
Communication mode
Communication Mode Setting
Callback times
When Liebert IntelliSlot 1 Communication mode is Modem, this parameter
sets the number of times a number is redialed to send an alarm notification.
Phone No.1
When Liebert IntelliSlot 1 Communication mode is Modem, this is the first
phone number to be dialed (to send an alarm notification).
Phone No.2
When Liebert IntelliSlot 1 Communication mode is Modem, this is the second
phone number to be dialed (to send an alarm notification).
Phone No.3
When Liebert IntelliSlot 1 Communication mode is Modem, this is the third
phone number to be dialed (to send an alarm notification).
Command password
User can modify the command password.