Equipment Location 7
5.0
E
QUIPMENT
L
OCATION
5.1
General Instructions
+DQGOHFDELQHWVLQDFFRUGDQFHZLWKWKHVDIHW\SUHFDXWLRQVLQ6HFWLRQ
,IQHFHVVDU\XVHD
VXLWDEOHPDWHULDOKDQGOLQJGHYLFHWRUHPRYHFDELQHWIURPWKHVKLSSLQJSDOOHW
([HUFLVH
H[WUHPHFDUHEHFDXVHRIWKHXQHYHQZHLJKWGLVWULEXWLRQ
&DUHIXOO\ORZHUWKHFDELQHWWR
WKHIORRU7KHFDVWHUVVKRXOGHQDEOHWKH836WREHSXVKHGWRWKHLQVWDOODWLRQORFDWLRQ
9HULI\WKDWWKH836V\VWHPLVLQVWDOOHGLQDFOHDQFRRODQGGU\ORFDWLRQ
,QVWDOODWLRQDQGVHUYLFHDELOLW\ZLOOEHHDVLHULIDGHTXDWHDFFHVVLVSURYLGHGRQDOOVLGHVRIWKH
HTXLSPHQWEXWRQO\IURQWDFFHVVLVUHTXLUHG
D 9HULI\WKDWWKHUHLVDGHTXDWHFOHDUDQFHWRRSHQFDELQHWGRRUV6HHGUDZLQJVDQGORFDOFRGHV
/LHEHUWUHFRPPHQGVIHHWRUPHWHURIVHUYLFHFOHDUDQFH
E9HULI\WKDWWKHUHLVDGHTXDWHDUHDLQIURQWRIFDELQHWWRSHUIRUPPDLQWHQDQFH
&KHFNZLWK
ORFDOFRGHV
F9HULI\WKDWWKHUHLVDGHTXDWHFOHDUDQFHDERYHDOOFDELQHWVWRDOORZH[KDXVWDLUWRIORZ
ZLWKRXWUHVWULFWLRQIHHWPLQLPXPXQREVWUXFWHG,ISRZHUDQGFRQWUROZLULQJDUHURXWHG
LQWRWKHWRSRIWKH836HQVXUHWKDWWKHFRQGXLWRUZLUHZD\GRHVQRWREVWUXFWUHPRYDORI
WKH836WRSSDQHO
5.2
Special Considerations for 1+1 Redundant Systems
&RQVLGHUWKHJURXQGLQJFRQILJXUDWLRQRI\RXUV\VWHPEHIRUHILQDOL]LQJPRGXOHSODFHPHQW
)RU
RSWLPDOJURXQGLQJSHUIRUPDQFHWKH1SRZHUPRGXOHVVKRXOGEHFORVHWRJHWKHU
)RURSWLPDOORDGVKDULQJSHUIRUPDQFHWKH836RXWSXWSRZHUFDEOHVVKRXOGEHDSSUR[LPDWHO\
WKHVDPHOHQJWKSOXVRUPLQXVSHUFHQW
3RVLWLRQPRGXOHVLQVXFKDZD\DVWRPLQLPL]HWKHOHQJWKRISRZHUFDEOHVDQGFRQWUROZLULQJ
EHWZHHQ836PRGXOHVDQGWKHSDUDOOHOLQJFDELQHW
%DWWHU\FDELQHWVVKRXOGJHQHUDOO\EHSRVLWLRQHGWRWKHOHIWVLGHRIWKH836PRGXOHVWRPDNHLW
HDVLHUWRFRQQHFWWKH836RXWSXWEXVEDUVWRWKH3DUDOOHOLQJ&DELQHWRU3DQHOERDUG
127(
7KH836KDVOHYHOLQJIHHWWRSUHYHQWWKH836IURPUROOLQJRQLWVFDVWHUV
DIWHULQVWDOODWLRQ7KHOHYHOLQJIHHWDUHQRWGHVLJQHGWRFDUU\WKHIXOOZHLJKW
RIWKH8367XUQWKHIHHWE\KDQGXQWLO´ILQJHUWLJKWµDJDLQVWWKHIORRU7KHQ
WLJKWHQDVPDOODPRXQWZLWKDZUHQFKOHVVWKDQWZRWXUQVWRJLYHDJRRG
IULFWLRQILWDJDLQVWWKHIORRU:KHQXVLQJVHLVPLFDQFKRULQJHQVXUHWKDWWKH
FDVWHUVDUHEHDULQJWKHZHLJKWRIWKH836
127(
7KH1SRZHU%DWWHU\&DELQHWFRPHVLQYHUVLRQVVSHFLILFWRHLWKHUWKHOHIWRU
ULJKWVLGHRIWKH836&RQWUROZLUHVDQGSRZHUFDEOHVDUHFXWWRGLIIHUHQW
OHQJWKVIRUWKHGLIIHUHQWYHUVLRQV)RUV\VWHPVZLWKPXOWLSOHEDWWHU\FDELQHWV
WKHFDELQHWVKDYHGLIIHUHQWSDUWQXPEHUVLQGLFDWLQJSODFHPHQWRIWKHFDELQHW
UHODWLYHWRWKH836$Q´$µRU´µGHVLJQDWLRQPHDQVWKHFDELQHWLVDGMDFHQW
WRWKH836&DELQHW´%µZLOOEHDGMDFHQWWRFDELQHW´$µDQGFDELQHW´&µLI
DSSOLFDEOHZLOODGMDFHQWWRFDELQHW´%µ
127(
,IWKHV\VWHPLQFOXGHVDPDWFKLQJ1SRZHU0DLQWHQDQFH%\SDVV&DELQHW
0%&WKH0%&LVJHQHUDOO\DWWDFKHGWRWKHULJKWVLGHRIWKH836FORVHVWWR
WKH836EXVEDUV7KH%DWWHU\&DELQHWVZRXOGWKHQEHPRXQWHGWRWKHOHIW
VLGHRRZHYHUERWKWKH0%&DQG%DWWHU\&DELQHWVDUHDYDLODEOH
LQERWKOHIWVLGHDQGULJKWVLGHFRQILJXUDWLRQVWRPHHWVLWHVSHFLILF
UHTXLUHPHQWV
Summary of Contents for Liebert Npower 30-130 kVA
Page 4: ......
Page 6: ......
Page 10: ......
Page 40: ...30 Installation Drawings 11 0 INSTALLATION DRAWINGS Figure 11 Outline Drawing 30 50 kVA UPS ...
Page 41: ...Installation Drawings 31 Figure 12 Outline Drawing 65 80 kVA UPS ...
Page 42: ...32 Installation Drawings Figure 13 Outline Drawing 100 130 kVA UPS ...
Page 45: ...Installation Drawings 35 Figure 16 Outline Drawing Maintenance Bypass Cabinet L Configuration ...
Page 46: ...36 Installation Drawings Figure 17 Outline Drawing Maintenance Bypass Cabinet N Configuration ...
Page 47: ...Installation Drawings 37 Figure 18 Outline Drawing Maintenance Bypass Cabinet P Configuration ...
Page 48: ...38 Installation Drawings Figure 19 Outline Drawing Maintenance Bypass Cabinet Q Configuration ...
Page 58: ...48 Installation Drawings Figure 29 Outline Drawing Seismic Anchoring 30 50 kVA UPS ...
Page 59: ...Installation Drawings 49 Figure 30 Outline Drawing Seismic Anchoring 65 80 kVA UPS ...
Page 60: ...50 Installation Drawings Figure 31 Outline Drawing Seismic Anchoring 100 130 kVA UPS ...
Page 61: ...Installation Drawings 51 Figure 32 Outline Drawing Remote Battery Breaker 30 130 kVA ...
Page 63: ...Installation Drawings 53 Figure 34 Outline Drawing Remote Battery Breaker with BIB Installed ...
Page 64: ...54 Installation Drawings Figure 35 Outline Drawing Remote Alarm Status Panel ...
Page 65: ...Installation Drawings 55 Figure 36 Outline Drawing LBS Control Panel ...
Page 66: ...56 Installation Drawings Figure 37 Outline Drawing LBS Alarm Status Contacts ...
Page 67: ...Installation Drawings 57 Figure 38 Outline Drawing LBS Transformer Panel ...
Page 70: ...60 Installation Drawings Figure 41 Control Wiring 30 130 kVA UPS ...
Page 73: ...Installation Drawings 63 Figure 44 Control Wiring Remote Alarm Status Panel Option ...
Page 74: ...64 Installation Drawings Figure 45 Control Wiring 2 or 3 Remote Alarm Status Panels ...
Page 76: ...66 Installation Drawings Figure 47 Control Wiring Site Scan Interface ...
Page 77: ...Installation Drawings 67 Figure 48 Control Wiring Programmable Relay Board Option ...
Page 78: ...68 Installation Drawings Figure 49 Control Wiring Input Contact Isolator Board ...
Page 79: ...Installation Drawings 69 Figure 50 Control Wiring NIC Option ...
Page 80: ...70 Installation Drawings Figure 51 Control Wiring Power Supply Option ...
Page 81: ...Installation Drawings 71 Figure 52 Control Wiring Internal Modem Option ...
Page 82: ...72 Installation Drawings Figure 53 Control Wiring AS 400 Signal Cable Option ...
Page 83: ...Installation Drawings 73 Figure 54 Control Wiring Open Wire Cable Adaptor Option ...
Page 84: ...74 Installation Drawings Figure 55 Control Connection Diagram 50 130 kVA ...
Page 85: ...Installation Drawings 75 Figure 56 Control Connection Location Diagram 30 130 kVA UPS ...
Page 86: ...76 Installation Drawings Figure 57 Terminal Details 30 50 kVA UPS ...
Page 87: ...Installation Drawings 77 Figure 58 Terminal Details 65 80 kVA UPS ...
Page 88: ...78 Installation Drawings Figure 59 Terminal Details 100 130 kVA UPS ...
Page 89: ...Installation Drawings 79 Figure 60 Schematic Diagram Maintenance Bypass Interlock System ...
Page 92: ...82 Installation Drawings Figure 63 Wiring Diagram UPS with Single Battery Cabinet ...
Page 98: ...88 ...
Page 99: ......