2
KTM
VIRGO SERIES E & U TOP ENTRY TRUNNION BALL VALVE
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
• If lifting lugs are not provided on the valve,
hold the valve with lifting strap around neck
area and gently lift it as shown in Figure 3.
Ensure the lifting strap is sized appropriately
for the weight that must be lifted and is
holding the neck area of valve firmly, to
prevent damages.
WARNING
• If the valve is supplied with an operator
(gear operator or actuator) do not use the
operator or the operator lifting lugs to lift the
valve assembly.
• For stem extension valve, use proper support
as shown in Figure 4 to prevent toppling
of valve.
• During handling, pay attention to prevent
any damage to the flange faces, butt weld
ends, operator, auxiliary fittings and piping
(as applicable). Do not drag the valve during
handling.
• The identification of the valve is given on the
body or on the nameplate or both. (Figure 5).
• If a tag number is specified by the customer,
identify the valve using tag number stamped
on the name plate or tag plate affixed to
the valve.
Lifting
straps
Body marking
Name plate
Size
matl
heat no.
WARNING
Do not lift from the
top flange of stem
extension
Always use lifting
hooks for lifting of
stem extension
Provide proper
support from here
to prevent toppling
FIGURE 3
FIGURE 5
FIGURE 4
• After removing from box, always store the
valve under roof and in a dry and clean
atmosphere, protected from rain and storm.
• Always place the valve on ‘soft’ surface like
rubber sheets or wooden planks free of dirt/
debris/hardware like nails and moisture to
avoid damage to the valve surfaces.
• Ensure that valve ends are covered with
protective end caps. Do not remove any
protection from the valve during storage
period.
• In case of automated valve assembly, refer to
actuator/accessory manufacturer instructions
for handling and storage.
• Always keep the valve either in fully open
or fully closed position. Full open position
is preferred. The valve is normally shipped
in the full open position (exception is valve
with a ‘fail close’ spring return actuator
arrangement)