Emerson KTM VIRGO E Series Installation, Operation And Maintenance Instructions Download Page 17

17

5

/

16

"

18

15

6

18

20

16

10

4

12

12

11

⅜"

16

26

10

22

34

28

15

6

18

20

16

½"

13

61

23

73

80

65

37

14

44

47

39

⅝“

11

118

44

141

155

126

71

26

85

92

76

¾“

10

206

77

245

270

219

122

45

145

160

130

⅞“

9

328

122

328

429

349

194

72

194

255

206

1“

8

488

182

488

639

519

289

108

289

378

307

1⅛“

8

706

263

578

925

751

414

154

339

544

440

1¼“

8

981

366

803

1285

1043

571

213

467

750

607

1⅜“

8

1320

492

933

1727

1404

763

284

479

1002

812

1½“

8

1727

644

1083

2261

1837

994

370

624

1305

1057

1⅝“

8

2211

824

1387

2894

2352

1266

472

794

1527

1347

1¾“

8

2777

1035

1742

3636

2954

1585

591

994

2080

1686

1⅞“

8

3433

1280

2153

4493

3651

1952

728

1224

2563

2076

2“

8

4183

1559

2624

5476

4449

2373

884

1489

3114

2524

2¼“

8

5997

2235

3762

7851

6379

3375

1258

2117

4418

3590

2½“

8

8271

3083

5188

10828

8797

4635

1728

2907

6068

4930

2¾“

8

11117

4144

6973

14591

11824

6208

2314

3894

8148

6603

3“

8

14481

5397

9084

19007

15403

8064

3006

5058

10583

8577

3¼“

8

18462

6881

11581

24232

19637

10256

3823

6433

13461

10909

3½“

8

23114

8615

14499

30336

24585

12812

4775

8037

16817

13627

3¾“

8

28485

10617

17868

37388

30298

15762

5875

9887

20688

16765

⅜” NPT

18

61

½" NPT

14

68

¾" NPT

14

75

1” NPT

11½

88

KTM 

VIRGO SERIES E & U TOP ENTRY TRUNNION BALL VALVE

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

FOR IMPERIAL SERIES (Nm)

Thread size
(Inch)

TPI

Non-coated bolts / nuts

Coated bolts / nuts

Low resistance bolt / 

stud material

High resistance bolt / 

stud material

Low resistance bolt / 

stud material grade

High resistance bolt / 

stud material

L7M, B7M

B8M 

Class 1

B8M 

Class 2

L7, B7

Gr 660

L7M, B7M

B8M 

Class 1

B8M 

Class 2

L7, B7

Gr 660

FOR NPT PLUG THREADS

Plug size

Thread per inch

Approx. torque (Nm)

The year of manufacture

Refer name plate affixed to the valve

Essential maximum / minimum allowable limits

Refer name plate affixed to the valve

The normal size for piping DN

Refer name plate affixed to the valve

Test pressure applied in bar and date

Refer tag plate affixed to the valve

Tare mass in kg

Refer tag plate affixed to the valve

The fluild group

Refer tag plate affixed to the valve

16 INFORMATION FOR PED 2014/68/EU COMPLIANT VALVE

NOTES

1.  Torque values given for NPT threads are only for 

reference, it may change depending upon accuracy 
of thread profile, sealing requirement, nature of 
the sealant used etc.

2.  As a general guideline, after hand-tight 

engagement, tighten 1-3 full turns so that you get 
'leak proof' joint.

15 SERVICE OF VALVES WITH API MONOGRAM

In case of repair and service of “API monogram” valve, service engineer shall consult Head- QA  
for any further actions.

Summary of Contents for KTM VIRGO E Series

Page 1: ...unnion Ball valve manufactured and supplied by Emerson Applicable to Soft Metal seated Cast EL UL subseries WARNING Always use Personal Protective Equipment PPE when carrying out above activities 2 RECEIPT HANDLING AND STORAGE Identify the valve contained in the box using the packing list fixed on the box While loading and unloading the box check for handling instructions symbols marked on the box...

Page 2: ...specified by the customer identify the valve using tag number stamped on the name plate or tag plate affixed to the valve Lifting straps Body marking Name plate Size matl heat no WARNING Do not lift from the top flange of stem extension Always use lifting hooks for lifting of stem extension Provide proper support from here to prevent toppling FIGURE 3 FIGURE 5 FIGURE 4 After removing from box alwa...

Page 3: ...p to DN 100 NPS 4 support to be provided at a distance of 2D to 3D from both valve ends For sizes DN 150 NPS 6 and higher support to be provided at distance D from both valve ends where D is the nominal diameter of pipeline For removing mounting support stand from valve assembly lift the valve above ground level by using appropriate material handling lifting equipment Refer handling section of thi...

Page 4: ...R OPERATOR OPEN CLOSE ADJUSTMENT HAS BEEN DONE PRIOR TO SHIPMENT AND MUST NOT BE CHANGED Rotation of hand wheel in the clockwise direction closes the valve and counterclockwise rotation opens the valve It is recommended that the valve should be opened and closed slowly to prevent hammering effect on the valve and pipeline If the valve is not operating to fully open or fully close position and or l...

Page 5: ...s Gear operator setting to be done as given in Section 5 3 5 3 Procedure for gear operator setting CAUTION If the valve has been supplied by Emerson with the gear operator assembled on the valve open close adjustment has been done prior to shipment and must not be changed In case of gear operator replacement or mounting of new gear operator on bare shaft valve the steps below shall be followed Fig...

Page 6: ...facturers like Climax Lubricants and Equipment Co Sealweld etc Sealant injection fitting Type A standard supply See Figure 13 Seat sealant injection Fully close the valve Remove the fitting end cap and slide giant buttonhead coupler Climax model 1699 1700 on sealant fitting Inject sealant into each of the sealant fitting Injection pressure shall be more than pipeline pressure but shall not exceed ...

Page 7: ...r temperature limits of the valve Do not exceed pressure and or temperature limits mentioned on name plate affixed to the valve 2 Valve material not suitable for service fluid Check Tag number as applicable and ensure correct valve is used as per process diagram Verify valve material mentioned on Name plate is suitable with service fluid 3 Use for control application These ball valves are designed...

Page 8: ... clean actuator vent Leakage through stem 1 Loose gland fasteners 1 Tighten the fasteners 2 Damaged stem stem sealing surface 2 Refurbish or replace the stem 3 Damaged stem seal 3 Replace the stem seal 4 Accumulation of dirt debris corrosion between stem and housing 4 Open valve clean and reassemble Leakage through body to bonnet joint bonnet to housing joint 1 Damaged seal gasket 1 Replace seal g...

Page 9: ...s uncompressed position Use bypass valves or completely shut off the process to isolate the valve from process pressure Relieve process pressure from both sides of the valve Drain the process media from both sides of the valve Ball valves can retain pressure and process fluid in cavity even after process pressure has been removed from both sides of the valve Relieve this pressure before disassembl...

Page 10: ...ll in fully closed position and then remove the operator from valve assembly Valve shall be positioned on clean and flat surface as shown in Figure 14 It is recommended to use original spares Graphite gaskets shall be replaced Elastomer and plastomer seals can be re used however it is recommended to replace them to maximize valve service life Protect every sealing surface from nicks dents and dama...

Page 11: ...o 12 9 Push the stem 5 out of its housing on the bonnet 2 10 Remove stem o rings 10c and backup rings if provided from bonnet and then remove graphite stem gasket 11a FIGURE 15 11 Remove stem thrust washer 22 from the stem 12 Insert the two hydraulic pistons inside body cavity and clamp the external profile of the spring holder ring 3a Refer assembly tool view 11 3 4 and Figure 15 13 Close the hyd...

Page 12: ...e hydraulic pistons from body 12 If the stem was disassembled from housing follow instructions from 13 to 16 otherwise go to Section 17 13 Insert stem thrust washer 22 over the stem 5 14 Insert stem o rings 10c along with backup rings 10c if provided inside the housing 6 KTM VIRGO SERIES E U TOP ENTRY TRUNNION BALL VALVE INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS 15 Install o ring 10d and...

Page 13: ... ring 4 Ball 5 Stem 6 Housing 7 Bearing retainer 8 ISO pad 9 Stem key 10 Body o ring 10a Seat o ring 10b Grease retaining o ring 10c Stem o ring 10d Housing o ring 11 Body gasket 11a Stem gasket 11b Housing gasket 12 Body studs 13 Body nuts 14 Housing capscrew 14a ISO pad capscrew 15 Springs 15a Antistatic spring 16 Stem grease fitting 16a Nipple 17 Seat grease fitting 18 Check valve 19 Vent bleed...

Page 14: ...ALL VALVE INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS 11 3 4 Assembly tool view Quantity Nr 2 For maintenance 1 valve Seat holder connection Seat holder connection Hydraulic piston double effect Hydraulic quick coupling female Close Open ...

Page 15: ...ur and hence PR pressure relief valve is mandatory with pre setting to avoid over pressure building in the cavity 13 GLAND PACKING ASSEMBLY PROCEDURE 1 In case of packing contain braided graphite it shall be placed at bottom and top Position of packing arrangement such that the oblique cut of these braided graphite is 180 apart Refer Figure below for appropriate arrangement for die molded and for ...

Page 16: ... 00 4298 1602 2696 5626 4572 2488 927 1561 3257 2646 M56 5 50 5343 1991 3352 6995 5683 3098 1155 1943 4056 3295 M60 5 50 6624 2469 4155 8671 7046 3824 1425 2399 5006 4067 KTM VIRGO SERIES E U TOP ENTRY TRUNNION BALL VALVE INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS 14 RECOMMENDED TIGHTENING TORQUES FOR FASTENERS AND PLUGS NOTES 1 Ensure that all the nuts bolts are tightened to the torque v...

Page 17: ... ENTRY TRUNNION BALL VALVE INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR IMPERIAL SERIES Nm Thread size Inch TPI Non coated bolts nuts Coated bolts nuts Low resistance bolt stud material High resistance bolt stud material Low resistance bolt stud material grade High resistance bolt stud material L7M B7M B8M Class 1 B8M Class 2 L7 B7 Gr 660 L7M B7M B8M Class 1 B8M Class 2 L7 B7 Gr 660 FOR...

Page 18: ...lely from faulty materials and workmanship within a period of 18 calendar months after the original goods shall have been first dispatched or 12 calendar months from the date of commissioning whichever is earlier provided that such defective parts are returned free to our works for examination The undertaking shall exclude any and every other obligation CAUTION Emerson does not assume responsibili...