3 mAintenAnCe

the Keystone CompoSeal is designed to require 
a minimum of maintenance.

Warning

Depressurize and, if necessary in case of 
dangerous fluids, drain the line and flush with 
appropriate cleaning fluid before starting any 
maintenance. Failure to do so may cause serious 
personal injury and/or equipment damage. 
Before disassembling the valve, ensure the valve 
has been decontaminated correctly from any 
harmful gasses or liquids and that it is within a 
safe temperature range for handling. Personnel 
making any adjustments to the valves should 
utilize suitable equipment. All required personal 
protection means should be worn. Only personnel 
trained in all aspects of manual and mechanical 
handling techniques must carry out handling of 
the valves.

3.1 routine Maintenance

Routine maintenance or lubrication is not 
required other than periodic inspection to 
ensure satisfactory operation and sealing.

3.2 reMoving tHe valve

1.  turn the disc to nearly closed position. 

(the disc is in line with the parallel flats).

2.  Loosen all flange bolts and remove the 

bolts.

3.  Spread the flanges with adequate tooling, 

and remove the valve.

3.3 valve disasseMbly

disassembly is not possible. the body halves 
are fixed by a one way connection.

Parts identification

1

body

2

disc stem

3

Seat

4

o-ring

ComPoSeAL wAfeR

Parallel flats

flange locating holes

mounting holes

top view

© 2017 Emerson. All rights reserved.

Summary of Contents for Keystone Figure 320

Page 1: ...the valve 1 Personnel making any adjustment to the valves should utilize suitable equipment All required personal protection means should be worn 2 The line must be depressurized before installing the valve 3 Installation and handling of the valves should only be done by personnel that is trained in all aspects of manual and mechanical handling techniques 4 Misuse of the valve is not allowed The v...

Page 2: ...flange gaskets can also be used When flange gaskets are used min 0 04 max 0 08 thick rubber gaskets are recommended the O rings must be removed from the body Use flange bolting in accordance with the appropriate standard Dmax min Do not use the valve as a crow bar to spread the flanges this might lead to damage to the flange area and or damage to the O ring sealing 2 3 Valve installation The valve...

Page 3: ...leaking Valve not fully closed Close valve Debris trapped in valve Cycle and flush with valve open to remove debris Seat is damaged Replace valve Jerky operation Debris trapped in valve Cycle and flush with valve open to remove debris Air supply actuator inadequate Increase air supply pressure and or volume 2 4 Valve verification Check the operation of the valve by operating it from fully open to ...

Page 4: ... utilize suitable equipment All required personal protection means should be worn Only personnel trained in all aspects of manual and mechanical handling techniques must carry out handling of the valves 3 1 Routine maintenance Routine maintenance or lubrication is not required other than periodic inspection to ensure satisfactory operation and sealing 3 2 Removing the valve 1 Turn the disc to near...