RUBBER
GROMMET

CLEVIS 
PIN

HAIRPIN
CLIP

MOTOR
YOKE

HANGER PIPE
ASSEMBLY

MOTOR WIRE (3)

RETENTION
CABLE (1)

MOTOR

HAIRPIN 
CLIP

CLEVIS
PIN

5/16-18
SETSCREW (2)

Figure 2

CANOPIES NOT
SHOWN FOR
CLARITY

4

5.

Slide the lower canopy down the
hanger pipe and securely tighten the
set-screw against the hanger pipe.
(See Figure 3.)

CAUTION: Blades come in balanced
sets of three. Do not mix blades if
installing more than one fan.

6.

Install the blade gaskets between the
blades and the motor. (See Figure 3.)

7.

Install the three blades onto the motor
using spring washers, M6 x 1/2" screws
and blade gaskets supplied. Securely
tighten the six blade screws.

It is critical that the clevis pin in the motor
coupling is properly installed and the
setscrews securely tightened. Failure to
verify that the pin and setscrews are
properly installed (as shown in Figure 3)
could result in the fan falling.

!

WARNING

To reduce the risk of personal injury, do
not bend the blade flanges when
installing the blades, balancing the
blades, or cleaning the fan. Do not insert
foreign objects between rotating fan
blades.

!

WARNING

BLADE

BLADE GASKET

SPRING WASHER
(2 PER BLADE)

M6 x 1/2" SCREW 
(2 PER BLADE)

Figure 3

3.

Align the clevis pin holes in the hanger
pipe with the holes in the motor yoke.
Install the clevis pin and secure with the
hairpin clip (Figure 2). The clevis pin
must go through the holes in the motor
yoke and the holes in the hanger pipe.
Push the straight leg of the hairpin clip
through the hole near the end of the
clevis pin until the curved portion of the
hairpin clip snaps around the clevis pin.
The hairpin clip must be properly
installed to prevent the clevis pin from
working loose. Pull on the rubber
grommet to make sure the clevis pin is
properly installed.

4.

Install and securely tighten the two
5/16-18 setscrews in the motor yoke
against the hanger pipe using the allen
wrench supplied. (Figure 2.)

U.L. Model No.: HF948, HF956

BP7311-2 48 56" Heat Fans  9/7/10  3:25 PM  Page 4

Summary of Contents for HF948BS01

Page 1: ...nce freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of your ceiling fan are not covered by this warranty This warranty also does not cover any defects malfunctions or f...

Page 2: ... outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The fan must be mounted with the fan blades at least 10 feet from the floor to prevent accidental contact with the fan blades 5 Suitable for use with solid state speed controls 6 Always properly connect the retention cable included w...

Page 3: ...Intermixing blades between fans can cause excessive wobble Keep blades in original sets of three Fan Assembly Instructions 1 Put the upper canopy and lower canopy on the hanger pipe assembly facing in the proper direction See Figure 1 NOTE For HF948 Only If you are going to use the 8 pipe first remove the hanger assembly from the 22 pipe and install it on the 8 pipe Be sure that the nut is securel...

Page 4: ...t in the fan falling WARNING To reduce the risk of personal injury do not bend the blade flanges when installing the blades balancing the blades or cleaning the fan Do not insert foreign objects between rotating fan blades WARNING BLADE BLADE GASKET SPRING WASHER 2 PER BLADE M6 x 1 2 SCREW 2 PER BLADE Figure 3 3 Align the clevis pin holes in the hanger pipe with the holes in the motor yoke Install...

Page 5: ...ing off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock WARNING To reduce the risk of fire electric shock or personal injury a The fan must be hung with at...

Page 6: ...UND WIRE BLACK SUPPLY HOT BLACK FAN WIRE GREEN WIRE GROUND FROM FAN WIRE CONNECTORS 3 WHITE SUPPLY NEUTRAL WHITE FAN WIRE Figure 9 2 Lift the fan onto the J hook and position as shown in Figure 7 Make sure the motor wires and retention cable at the top of the hanger pipe are positioned behind J hook as illustrated in Figure 7 CAUTION The electrical wires and retention cable must not be placed betw...

Page 7: ...as a result of tight cable if this should happen shut off power supply and re check instructions to correct problem NOTE When any solid state motor speed control is used a humming noise may be present in the fan on low speed This hum in no way affects the operation of the fan and is acceptable in most industrial installations To avoid possible electrical shock be sure electricity is turned off at ...

Page 8: ... Setscrews 2 ea 10 Hairpin Clip 11 Clevis Pin 12 Cable Clamp 2 each 13 Screw M6 x 1 2 6 each 14 Spring Washer M6 6 each 15 Blade Gasket 3 each 16 Wire Connector 3 each 17 Allen Wrench Owner s Manual BP7311 2 BP7311 2 BP7311 2 BP7311 2 BP7311 2 Repair Parts Listing 1 2 4 5 6 10 11 17 13 12 16 14 7 15 8 9 3 Before discarding packaging material be certain all parts have been removed HOW TO ORDER REPA...