background image

2

WARNING: 

To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions

1. Read your owner’s manual carefully and keep it for future reference.

2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting

means to prevent power from being switched on accidentally. When the service disconnecting means cannot
be locked, securely fasten a warning device, such as a tag, to the service panel.

3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to

the ceiling fan before servicing.

4. Suitable for use with solid-state speed controls.

5. Do not bend the blade flanges when installing the blades, balancing the blades, or cleaning the fan. Do not

insert foreign objects in between the rotating blades.

Additional Safety Instructions for Installation

1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan

without blades.

2. All wiring must satisfy National and Local Electrical Codes. Use the National Electrical Code if Local Codes do

not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical
installation should be made or approved by a licensed electrician.

3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50 pounds. Use

only U.L. outlet boxes listed as “Acceptable for Fan Support of 50 lbs or less”, and use the mounting screws
provided with the outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable
for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

4. The fan must be mounted with the fan blades at least 10 feet from the floor to prevent accidental contact with

the fan blades.

5. Suitable for use with solid-state speed controls.

6. Always properly connect the safety cable included with this fan (follow the “Installation Instructions” section

carefully).

7. The support beam or joist must be secure and capable of supporting at least 50 pounds.

8. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know

enough about electrical wiring, have your fan installed by a licensed electrician.

WARNING: 

To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically

approved for this fan.

WARNING:

This product is designed to use only those parts supplied with this product and/or any accessories

designated specifically for use with this product by Emerson Company. Substitution of parts or accessories not
designated for use with this product by Emerson Company could result in personal injury or property damage.

WARNING: 

To Reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges,

balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

WARNING

!

DATE CODE:

The date code of this fan may be found on

the box, stamped in ink on a white label.

You should record this data above and keep

it in a safe place for future use.

Summary of Contents for HF1160WW 00

Page 1: ...n authorized service center call 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The gl...

Page 2: ...lbs or less and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The fan must be mounted with the fan blades at least 10 feet from the floor to prevent accidental contact with the fan blades 5 Suitable for use with solid stat...

Page 3: ...s CAUTION The blade assemblies must be mounted on the motor assembly so that the This Side Up label is visible at the top of the motor Figure 1 1 Install one blade assembly on the top of the motor assembly using two M6 1 0 x 12mm Phillips hex head screws two split lockwashers and two flat washers supplied Figure 1 Repeat this procedure for the remaining two blade assemblies Electrical Requirements...

Page 4: ... yoke It is critical that the clevis pin in the motor yoke is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly installed could result in the fan falling 4 It is critical that the clevis pin in the motor coupling is properly installed and the setscrews securely tightened Failure to verify that the pin and setscrews are properly instal...

Page 5: ...and green leads on one side of the outlet box and the black leads on the other side of the outlet box 13 Screw the two 3 4 threaded studs supplied into the tapped holes in the hanger bracket Figure 8 14 Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the ceiling cover Figure 9 15 Secure the ceiling cover in place by sliding lockwashers over the th...

Page 6: ... cable through the eye screw and then back through the two cable clamps CAUTION It is important to note the proper installation position of the cable clamps as illustrated in Figure 10 TO obtain maximum holding power install U bolt section of clip on dead or short end of cable and saddle on long end of cable Improper installation reduces the efficiency of the connection by as much as 40 percent 17...

Page 7: ...ad Knurled M4 7 x 10mm 2 14 Lockwasher External Tooth M4 2 15 Wrench Setscrew 16 Clamp Safety Wire 2 17 Screw Eye 18 Cover Ceiling 762516 3 762516 15 19 Cover Motor 762494 762494 1 20 Capacitor 4 5 uF 762493 762493 21 Blade set of 3 762495 762495 1 22 Flange set of 3 762497 762497 1 Owner s Manual BP7272 BP7272 Before discarding packaging material be certain all parts have been removed HOW TO ORDE...

Page 8: ...15 16 10 11 12 5 6 13 17 21 20 22 14 19 T H I S S I D E U P Part No F40BP72720000 Printed in Taiwan 02 04 Form No BP7272 Air Comfort Products DIVISION OF EMERSON COMPANY 8100 W Florissant St Louis MO 63136 Repair Parts ...