24
FXMP25 User Guide
www.controltechniques.com
Issue Number: 3
4
Not used
5 (+10V)
10V user output
Function
Supply for Analog input terminal
Voltage tolerance
2 %
Rated output current
5 mA
Protection
Over 5 mA, the current is limited, but
there is no trip (Voltage is less than 10 V
if the current is higher than 5 mA)
6 (
I
f)
Field current output signal
7 (Va)
Armature voltage output signal
Type
Single-ended voltage
Voltage range
0 to 10 V
Maximum output current
5 mA
Load resistance
2 k
Ω
min
Protection
5 mA short circuit protection
Resolution
10 bits
Update period
4 ms
8
Fail relay common
9
Fail relay normally open
10
Fail relay normally closed
Function
FXMP25 OK indicator
(See Pr
01
and
Pr
27
.
Type
Form C
Rating
250/125 Vac category 1/2
5 A nominal resistive load
5 A 30 Vdc
Contact condition
Energized when power applied and
FXMP25 OK
Update period
4 ms
Status relay contact is over-voltage category II.
WARNING