Instruction Manual
D104548X012
V200U Valve
May 2020
3
Table 2. Valve Body Materials, End Connections, and Ratings
VALVE BODY
MATERIAL
VALVE SIZE, DN
VALVE SIZE, NPS
FLANGELESS VALVE END CONNECTION COMPATIBILITY
ASME B16.5
EN1092-1
Raised Face Flange
Type B Raised Face Flange
CL150
CL300
PN10
PN16
PN25
PN40
EN 1.4408/CF8M
80
3
X
X
X
X
X
X
100
4
X
X
X
X
X
X
150
6
X
X
X
X
X
X
200
8
X
X
X
X
X
X
250
10
X
X
X
X
X
X
Table 3. V200U Approximate Weights
VALVE SIZE
RATING
WEIGHT
DN
NPS
kg
lbs
80
3
CL150
8
18
CL300
10
22
PN10-40
9
19
100
4
CL150 and 300
13
28
PN10/16
12
26
PN25/40
13
28
150
6
CL150 and 300
27
58
PN10-40
200
8
CL150 and 300
49
109
PN10/16
PN25/40
250
10
CL150
64
140
CL300
102
225
PN10/16
64
140
PN25/40
71
156
Installation
Installation steps are provided in this section for V200U valves. Key numbers in installation procedures are shown in
figure 14 and 15 unless otherwise indicated.
WARNING
Always wear protective gloves, clothing, and eyewear when performing any installation operations to avoid personal
injury.
Personal injury or equipment damage caused by sudden release of pressure may result if the valve assembly is installed
where service conditions could exceed either the valve body rating or the mating pipe flange joint rating. To avoid such
injury or damage, provide a relief valve for overpressure protection as required by government or accepted industry codes
and good engineering practices.
Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this
instruction manual.