background image

Type EZR

Europe, Middle East and 

Africa Only

Summary

Introduction ......................................................................... 1

Description.......................................................................... 1

Characteristics .................................................................... 2

Labelling ............................................................................. 4

Operation ............................................................................ 5

Dimensions and Weights .................................................... 6

Installation .......................................................................... 7

Commissioning ................................................................... 9

Maintenance ....................................................................... 10

Spare Parts......................................................................... 13

INTRODUCTION

The 

Type EZR 

is a pilot-operated regulator used in 

transmission and distribution networks or pipe lines 

supplying industries and commercial businesses.

The 

Type EZR

 can be equipped with a slam shut Type OS2 

(Type EZR body change) which permits the gas flow to be 

cut off rapidly and totally in the case of under or over outlet 

regulator pressure.

Description

Main Valve

The Type EZR consists of:

A version without integral slam shut:

•  A body («E body» type), a bonnet

•  A regulation subassembly consisting of a slotted cage and 

a diaphragm/plug

•  A travel indicator, an inlet screen

•  A pilot assembly consisting of a filter, an adjustable restrictor 

and a pilot

A version with integral slam shut:

• 

A body («X body» type), a bonnet, a connecting part

•  A regulation subassembly consisting of a slotted cage 

and a diaphragm/plug

•  A travel indicator

•  A pilot assembly consisting of a filter, an adjustable restrictor 

and a pilot

•  A slam shut orifice

•  A integral O-ring tightshut valve/bypass assembly

•  A release relay Type OS2 according to 

D103683X012_OS2_IM:

  -  a mechanism box (BM)

  -  a safety manometric box (BMS) to be connected outlet 

side of the regulator

Pilot-Operated Regulator

Instruction Manual

D103681X012
January 2020

The 

Type EZR

 is in conformity with the 

PED 2014/68/EU and is classified in Category IV.

Figure 1. 

Type EZR Pilot-Operated Regulator

Summary of Contents for Fisher EZR

Page 1: ...pe a bonnet A regulation subassembly consisting of a slotted cage and a diaphragm plug A travel indicator an inlet screen A pilot assembly consisting of a filter an adjustable restrictor and a pilot A version with integral slam shut A body X body type a bonnet a connecting part A regulation subassembly consisting of a slotted cage and a diaphragm plug A travel indicator A pilot assembly consisting...

Page 2: ...rol line This pilot is used in monitoring systems requiring an isolated pilot bleed exhaust Type 161EBH The high pressure version of the Type 161EB pilot with an outlet pressure range from 17 2 to 48 3 bar Type 161EBHM The high pressure version of the Type 161EBM pilot with an outlet pressure range from 17 2 to 48 3 bar Regulator Options Travel Indicator Relief Size reduction Trim CHARACTERISTICS ...

Page 3: ...lot Pressure Ranges Type Outlet Pressure Range bar Pilot Control Spring Information Spring Color Part Number PRX 120 PRX 125 1 0 to 1 8 1 8 to 3 0 3 0 to 5 5 5 5 to 8 5 Yellow Green Blue Black M0255240X12 M0255230X12 M0255180X12 M0255220X12 8 5 to 14 5 14 5 to 23 0 23 0 to 30 0 30 0 to 40 0 Silver Gold Aluminium Red M0255210X12 M0255200X12 M0255860X12 M0255190X12 PRX 120 AP PRX 125 AP 30 0 to 80 0...

Page 4: ...V EZR SECURITE SLAM SHUT GROUPE 1 N série serial Date Fab Test Mfg Test date Cat PS norme standard norme standard EN 334 mode défaillance failure mode classe sécurité slam shut class DN PN Pumax bar FISHER FRANCEL PT bar Temp TS 17 66 C Class Type Cg matériau shell A352LCC A350LF2 OS2 Standard EN 14382 BMS 027 017 BMS 162 BMS 236 315 BMS 071 Min only All Max Min Types of BMS Security Class A B BMS...

Page 5: ...of the pilot diaphragm is overcome by the force of the spring the pilot closes The pressure loss through the pilot restrictor decreases The force of the closing spring and that of the Pm becomes superior to that provoked by the Pu the regulator CLOSES Slam Shut The pressure of the zone to be protected generally the pipeline on the outlet side of the regulator and after the slam shut is sensed by t...

Page 6: ...4 Table 7 Dimensions mm Type EZR part 1 Body DN B C E Type 161EB Pilot Type PRX Pilot 25 220 62 335 239 50 226 83 340 245 80 343 105 392 297 100 372 137 433 336 150 420 178 465 368 Table 8 Weights kg Type EZR Body DN CL150 RF CL300 RF CL600 RF 25 12 14 16 50 26 27 31 80 50 51 57 100 67 73 88 150 97 108 161 Table 9 Dimensions mm Types EZR and EZR OS2 part 2 Body DN A D J M PN CLASS 16 25 40 150 300...

Page 7: ...rsting of pressure containing parts To avoid such injury and damage install the regulator in a safe location Only personnel qualified through training and experience should install operate and maintain a regulator Before installation make sure that there is no damage to or debris in the regulator Also make sure that all tubing and piping are clean and unobstructed The regulator is installed on hor...

Page 8: ...e is protected by an appropriate device s to avoid exceeding the limits of utilization PS TS Verify that the limits of utilization correspond to the appropriate operating conditions Version with integral slam shut verify that the safety manometric box BMS and spring correspond to the appropriate operating conditions on the outlet side of the regulator The equipment should not receive any type of s...

Page 9: ...t release relay stage Set Stage 1 Slam shut valve plug Open Stages 2 and 3 Progressively increase the pressure to reach tripping Adjust setting if necessary D103683X012_OS2_IM Note the set point value on the equipment or mark it on a commissioning document Positions before commissioning Impulse line isolating valve Open Impulse line atmospheric valve Closed Slam shut valve plug Closed Servicing va...

Page 10: ... pressure increases Internal leak Control the slam shut valve plug Control the slam shut Control the bypass or contact after sales If the outlet pressure is constant Slam shut valve plug is tightshut Type EZR 10 Europe Middle East and Africa Only MAINTENANCE Operations concerning the integral slam shut version are in italic Servicing Check Recommended frequency Twice yearly minimum Verification Se...

Page 11: ...Body DN In Screw keys 1 and 11 Spanner in Screw keys 1 and 11 Torque N m Fixation keys 18 Connector key 19 Bypass key 15 25 1 9 16 12 x 1 3 4 13 16 110 8 130 14 50 2 1 2 13 x 1 1 2 3 4 110 9 130 14 80 3 5 8 11 x 1 3 4 15 16 175 28 280 20 100 4 3 4 10 x 2 1 4 1 1 8 260 28 280 24 150 6 1 8 x 2 3 4 1 1 2 510 70 410 24 ...

Page 12: ...alves closed Bleed off outlet pressure Bleed off inlet pressure Unscrew the pilot impulse connection Unscrew the screws key 1 fixing the bonnet key 2 Remove the bonnet key 2 Remove the diaphragm plug assembly key 3 Remove the slotted cage key 4 the O ring key 5 the strainer key 6 or the space washer key 6 Clean parts and replace them if necessary Pilot Unscrew the manometric box screws Remove the ...

Page 13: ...ts List Description Key Reference Pilot Type 161EB 161EBH 161EBM 161EBHM Pilot kit 0 34 to 13 8 bar 15 R161X000012 R161MX00012 Pilot kit 13 8 to 24 1 bar 15 R161X000022 R161MX00022 Pilot kit EBH M 16 R161HX00012 R161HMX0012 O ring 17 1C8538X0052 Filter cartridge 18 17B6813X012 O ring 19 1F269206992 SAV kit 0 34 to 13 8 bar 1 197435 197438 SAV kit 13 8 to 24 1 bar 1 197436 197439 SAV kit 24 1 to 48...

Page 14: ...kit PN 20 6 to 14 197428 197429 197431 197432 197434 SAV kit PN 50 100 6 to 14 197428 197430 197431 197433 197434 with without slam shut O ring 6 18B3438X012 18B3438X012 10A8931X012 10A8931X012 10A3800X012 O ring 7 1H2926X0032 1H2926X0032 1D191706992 1D191706992 1D191706992 O ring 8 13A1584X052 13A1584X052 10A3803X062 10A3803X062 T12050X0012 O ring 9 19B2838X012 18B2124X012 18B8514X012 18B2140X012...

Page 15: ...1 22 23 24 A B 18 11 26 25 R106 R108 R109 R110 R107 Type EZR 15 Europe Middle East and Africa Only Type PRX 120 or PRX 125 Type PRX 120 or PRX 120 AP Type PRX 120 AP or PRX 125 AP Type PRX 125 or PRX 125 AP S SUPPLY PORT B BLEED PORT L LOADING PORT A SENSING PORT D DAMPER R RESTRICTOR Figure 14 Type PRX Series Pilots Figure 15 Type FU Filter ...

Page 16: ...rs Fisher is a mark owned by Fisher Controls International LLC a business of Emerson Automation Solutions The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or their use or applicabi...