Startup

The regulator is factory set at approximately the midpoint of the 

spring range or the pressure requested, so an initial adjustment 

may be required to give the desired results. With proper installation 

completed and relief valves properly adjusted, slowly open the 

upstream and downstream shutoff valves.

Adjustment

To change the outlet pressure, remove closing cap or loosen the 

locknut and turn the adjusting screw clockwise to increase outlet 

pressure or counterclockwise to decrease pressure. Monitor the 

outlet pressure with a test gauge during the adjustment. Replace 

closing cap or tighten the locknut to maintain the desired setting.

Taking Out of Service (Shutdown)

!

WARNING

To avoid personal injury resulting from sudden 

release of pressure, isolate the regulator from all 

pressure before attempting disassembly.

Parts List

Key Description

Regulator Body

Spring Case

Closing Cap

Adjusting Screw

Regulator Spring

Relief Valve Spring

Spring Seat

8 Pin

Relief Valve Seat

10 

Diaphragm Plate

11 

Disk Holder

12 

Fulcrum Rod

13 

Machine Screw

Key Description

14 

Machine Screw

15 Diaphragm

16 

Vent Screen

17*  Closing Cap Gasket

18 

 Closing Spring, for 912N Series  

  with handwheel only

19 

 Spacer Ring, for 912N Series  

  with handwheel only

20 

 Lockwheel, for 912N Series 

  with handwheel only

25 

 Spring Seat, for 912N Series  

  with handwheel only

29* Disk

*Recommended spare part

1/8 NPT

1/8 NPT

FOR TYPE 912H 

ONLY (LOCATE 

PER T10895)

Figure 1.

 912N Series Pressure Regulator Assembly

Figure 2.

 912N Series with Handwheel Construction Assembly

BB7822

BC2347

912N Series

Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/emerson-automation-solutions
Twitter.com/emr_automation

[email protected]

Emerson Automation Solutions

For further information on the current 

PED revision see Bulletin: 

D103053X012

or scan the QR code.

Fisher.com

Americas

 

McKinney, Texas 75070 USA 

T   +1 800 558 5853 

+1 972 548 3574

Europe

 

Bologna 40013, Italy 

T  +39 051 419 0611

Asia Pacific

 

Singapore 128461, Singapore 

T  +65 6777 8211

Middle East and Africa 

Dubai, United Arab Emirates 

T  +971 4 811 8100

D100317X014 © 2002, 2019 Emerson Process Management Regulator 

Technologies, Inc. All rights reserved. 04/19. 

The Emerson logo is a trademark and service mark of Emerson 

Electric Co. All other marks are the property of their prospective owners. 

Fisher™ is a mark owned by Fisher Controls International LLC, a 

business of Emerson Automation Solutions.
The contents of this publication are presented for information purposes 

only, and while effort has been made to ensure their accuracy, they are 

not to be construed as warranties or guarantees, express or implied, 

regarding the products or services described herein or their use or 

applicability. All sales are governed by our terms and conditions, which 

are available on request. We reserve the right to modify or improve the 

designs or specifications of our products at any time without notice.

Emerson Process Management Regulator Technologies, Inc does not 

assume responsibility for the selection, use or maintenance of any 

product. Responsibility for proper selection, use and maintenance of any 

Emerson Process Management Regulator Technologies, Inc. product 

remains solely with the purchaser.

Reviews: