background image

1

2

5

6

4

9

9

3

7

11

12

13

14

15

16

27

37

36

32

22 21 20 19 23 18 17

35 34

10 30

CB2197_E

Figure 2. 

Spring Loaded Type 630 Regulator -  

High-Pressure Construction

Parts List

Key Description 

Adjusting Screw

Hex Nut

Spring Case

Upper Spring Seat

5 Spring

Cap Screw

Lower Spring Seat

Diaphragm Plate, Low-Pressure only

Cap Screw, For use with steel diaphragm adaptor

10 

Cap Screw, For use with cast iron diaphragm adaptor

11* Diaphragm

12 

Connector Head Assembly

13 

Diaphragm Adaptor

14 

Lever Assembly

15 Pin

16* Gasket

17 

Cap Screw

18 

Inlet Adaptor

19*  Inlet Body Gasket

20*  Orifice

21*  Valve Disk Assembly Type 630 only

21 

O-ring Holder (Type 630R only)

22 

Valve Carrier

23 Body

27 

Vent Assembly, Type Y602-12

30 

Hex Nut, For use with cast iron diaphragm adaptor

31 

Cap Screw (not shown)

32 

O-ring Washer (Type 630R only)

33 

Plug, For DN 50 / 2 in. bodies only (not shown)

34 Nameplate

35 

Drive Screw

36 

Machine Screw (Type 630R only)

37*  O-ring (Type 630R only)

43 

Diaphragm protector, use only when specified (not shown)

52 

NACE Tag (not shown)

53 

Tag Wire (not shown)

CD3355_E

Figure 3. 

Spring Loaded Type 630R Relief Valve

High-Pressure Construction

*Recommended spare part.

1

2

5

6

4

9

9

3

7

11

12

13

14

15

16

27

22

21

20

19

23

18

17

35 34

10 30

A

A

630 Series

Facebook.com/EmersonAutomationSolutions
LinkedIn.com/company/emerson-automation-solutions
Twitter.com/emr_automation

[email protected]

Emerson Automation Solutions

For further information on the current 

PED revision see Bulletin: 

D103053X012

or scan the QR code.

Fisher.com

Americas

 

McKinney, Texas 75070 USA 

T   +1 800 558 5853 

+1 972 548 3574

Europe

 

Bologna 40013, Italy 

T  +39 051 419 0611

Asia Pacific

 

Singapore 128461, Singapore 

T  +65 6777 8211

Middle East and Africa 

Dubai, United Arab Emirates 

T  +971 4 811 8100

D100300X014 © 2009, 2019 Emerson Process Management Regulator 

Technologies, Inc. All rights reserved. 01/19. 

The Emerson logo is a trademark and service mark of Emerson 

Electric Co. All other marks are the property of their prospective owners. 

Fisher™ is a mark owned by Fisher Controls International LLC, a 

business of Emerson Automation Solutions.
The contents of this publication are presented for information purposes 

only, and while effort has been made to ensure their accuracy, they are 

not to be construed as warranties or guarantees, express or implied, 

regarding the products or services described herein or their use or 

applicability. All sales are governed by our terms and conditions, which 

are available on request. We reserve the right to modify or improve the 

designs or specifications of our products at any time without notice.

Emerson Process Management Regulator Technologies, Inc does not 

assume responsibility for the selection, use or maintenance of any 

product. Responsibility for proper selection, use and maintenance of any 

Emerson Process Management Regulator Technologies, Inc. product 

remains solely with the purchaser.

Summary of Contents for Fisher 630 Series

Page 1: ...stalled operated and maintained in accordance with international and applicable codes and regulations and Emerson Process Management Regulator Technologies Inc instructions If the regulator vents fluid or a leak develops in the system it indicates that service is required Failure to take the regulator out of service immediately may create a hazardous condition Personal injury equipment damage or l...

Page 2: ... loaded constructions have a screened vent assembly key 27 Figures 1 2 and 3 installed in the 1 4 NPT spring case vent opening If a remote vent is required remove the vent assembly and install a remote vent line Overpressure Protection The recommended pressure limitations are stamped on the regulator nameplate Some type of overpressure protection is needed if the actual inlet pressure exceeds the ...

Page 3: ...e 630R Relief Pressure Ranges Startup The regulator is factory set at approximately the midpoint of the spring range or the pressure requested so an initial adjustment may be required to give the desired results With proper installation completed and relief valves properly adjusted slowly open the upstream and downstream shutoff valves Adjustment To change the set pressure remove the closing cap o...

Page 4: ...om emr_automation Webadmin Regulators emerson com Emerson Automation Solutions For further information on the current PED revision see Bulletin D103053X012 or scan the QR code Fisher com Americas McKinney Texas 75070 USA T 1 800 558 5853 1 972 548 3574 Europe Bologna 40013 Italy T 39 051 419 0611 Asia Pacific Singapore 128461 Singapore T 65 6777 8211 Middle East and Africa Dubai United Arab Emirat...

Reviews: