![Emerson Fisher 4660 Instruction Manual Download Page 5](http://html.mh-extra.com/html/emerson/fisher-4660/fisher-4660_instruction-manual_102283005.webp)
Instruction Manual
D200163X012
4660 Pressure Pilot
June 2017
5
Table 4. Maximum Allowable Process Pressure
(1)
BOURDON TUBE RATING
MAXIMUM ALLOWABLE EMERGENCY PROCESS PRESSURE
Stainless Steel Bourdon Tubes
NACE Compliant Bourdon Tubes
Bar
(2)
Psig
Bar
(2)
Psig
Bar
(2)
Psig
6.9
17.2
34.5
69.0
100
250
500
1000
13.8
34.2
69.0
138.0
200
500
1000
2000
13.8
34.2
69.0
138.0
200
500
1000
2000
103.4
172.4
344.8
517.2
689.5
1500
2500
5000
7500
10,000
206.8
344.8
517.2
646.3
N/A
3000
5000
7500
9375
N/A
206.8
258.6
430.9
568.8
758.5
3000
3750
6250
8250
11,000
Maximum Allowable Process Pressure to Insure Set Point Readjustability
(3)
6.9
17.2
34.5
69.0
100
250
500
1000
13.8
34.8
51.7
103.5
200
500
750
1500
13.8
22.3
53.4
89.7
200
325
775
1300
103.4
172.4
344.8
517.2
689.5
1500
2500
5000
7500
10,000
155.1
172.4
517.2
646.3
N/A
2250
2500
7500
9375
N/A
124.0
227.5
344.8
517.2
689.5
1800
3300
5000
7500
10,000
1. Normal operating process pressures should not exceed the Bourdon tube rating.
2. Ratings indicated on Bourdon tube are in psig and kPa (1 bar = 100 kPa).
3. Values listed for NACE compliant Bourdon tubes are for a 2% deviation from set point due to overpressure.