CV500 Valve
Instruction Manual
Form 5302
July 2006
2
Table 1. Specifications
Valve Sizes
J
3-,
J
4-,
J
6-,
J
8-,
J
10-, and
J
12-inch
End Connection Style
J
Raised-face flanges or
J
ring-type joint flanges
(ASME B16.5). Valve bodies with PN10 through
PN100 flanges also available. Various flangeless
(wafer) valve body sizes are available in certain
ASME and PN ratings. Consult your Emerson
Process Management
t
sales office
Maximum Inlet Pressure
(1)
Consistent with applicable ASME or PN flange
ratings
Maximum Pressure Drops
(1)
Shutoff Classification
Class IV per ANSI/FCI 70-2 and IEC 60534-4,
(0.01% of valve capacity at full travel), for either
flow direction
Flow Characteristic
Approximately equal percentage
Flow Direction
J
Forward (normal) flow is into the convex side of
the V-notch ball
J
Bidirectional flow is into either side of the
V-notch ball
Actuator Mounting
J
Right-hand or
J
left-hand as viewed from the
upstream side of the valve
Mounting position depends on the desired open
valve position and flow direction required by
operating conditions
Valve Ball Rotation
Counterclockwise to close (when viewed from
actuator side of valve body) through 90 degrees
of ball rotation
Valve Body/Actuator Action
With diaphragm or piston rotary actuator,
field-reversible between
J
push-down-to-close
(extending actuator rod closes valve body) and
J
push-down-to-open (extending actuator rod
opens valve body)
Shaft Diameters
(2)
and Approximate Weights
1. The pressure/temperature limits in this manual and any applicable standard limitations should not be exceeded.
2. Shaft diameter and spline end must match available shaft diameter of actuator.
Description
The Design CV500 Cam-Vee-Ball rotary control
valve, has a Vee-Ball
r
style segmented ball in a
valve body similar to the Design V500 valve. The
Design CV500 is a flanged (figure 1) or wafer (figure
2) valve with a self-centering seat, eccentrically
rotating V-notch ball, and splined valve shaft.
Suitable for forward or reverse flow use, this valve
mates with a variety of actuators to provide throttling
or on-off service. Both flanged and wafer valves
mate with ASME flanges or DN flanges.
No person may install, operate, or maintain a Design
CV500 valve without first
D
being fully trained and
qualified in valve, actuator, and accessory
installation, operation, and maintenance, and
D
carefully reading and understanding the contents of
this manual. If you have any questions concerning
these instructions, contact your Emerson Process
Management sales office before proceeding.
Specifications
Specifications for the Design CV500 rotary control
valve are listed in table 1 and 51.3:CV500.
Note
Neither Emerson
r
, Emerson Process
Management, Fisher
r
, nor any of their
affiliated entities assumes
responsibility for the selection, use
and maintenance of any product.
Responsibility for the selection, use,
and maintenance of any product
remains with the purchaser and
end-user.