XRi77CX-CH
9/9
FCC_nt
Condenser fan mode operation
O_n
Pr2
FCo_nt
Condenser fan on after switching off the compressor
0
Pr2
ACH_nt
Kind of action for auxiliary regulator
CL
Pr2
SAA_nt
Set point for auxiliary regulator
0.0
Pr2
SHy_nt
Differential for auxiliary regulator
1.0
Pr2
ArP_nt
Probe selection for auxiliary regulator
nP
Pr2
Sdd_nt
Auxiliary regulator disabled during any defrost
no
Pr2
ALP_nt
Probe selection for temperature alarms
P1
Pr1
ALC_nt
Temperature alarms configuration: relative, absolute
rE
Pr1
ALU_nt
Maximum temperature alarm
5.0
Pr1
ALL_nt
Minimum temperature alarm
5.0
Pr1
AFH_nt
Temperature alarm recovery differential
1.0
Pr1
ALd_nt
Temperature alarm delay
15
Pr1
dAo_nt
Temperature alarm delay after power-on
01:30
Pr1
AP2_nt
Probe selection for second temperature alarms
nP
Pr2
AL2_nt
Second low temperature alarm
-100.0
Pr2
AU2_nt
Second high temperature alarm
150.0
Pr2
AH2_nt
Differential for second temperature alarm recovery
2.0
Pr2
Ad2_nt
Second temperature alarm delay
5
Pr2
dA2_nt
Delay for second temperature alarm after power-on
01:00
Pr2
bLL_nt
Compressor off due to second low temperature alarm
no
Pr2
AC2_nt
Compressor off due to second high temperature alarm
yes
Pr2
SAF_nt
Differential for anti freezing control
3.0
Pr2
tbA_nt
Alarm relay switched off by pushing any key
yes
Pr2
oA1_nt
Relay output oA1 configuration
dEF
Pr2
oA2_nt
Relay output oA2 configuration
Fan
Pr2
oA3_nt
Relay output oA3 configuration
LiG
Pr2
oA4_nt
Relay output oA4 configuration
ALr
Pr2
oAn_nt
Analogue output configuration
FrE
Pr2
AOP_nt
Alarm relay polarity
CL
Pr2
i1P_nt
Digital input 1 polarity
CL
Pr1
i1F_nt
Digital input 1 configuration
dor
Pr1
i2P_nt
Digital input 2 polarity
CL
Pr2
i2F_nt
Digital input 2 configuration
EAL
Pr2
did_nt
Digital inputs 1 alarm delay
1
Pr1
d2d_nt
Digital inputs 2 alarm delay
1
Pr2
nPS_nt
Number of pressure alarm switch before stopping the
regulation (Lock alarm)
15
Pr1
OdC_nt
Compressor and fan status after door opening
F-C
Pr1
rrd_nt
Regulation restart after open door alarm
yes
Pr1
HES_nt
Differential for energy saving mode
0
Pr1
LdE_nt
Energy saving mode controls the lights (lights off
when energy saving goes active)
yes
Pr1
Hur_nt
Hours
Pr1
Min_nt
Minutes
Pr1
dAY_nt
Day of the week
Pr1
dyM_nt
Day of the month
Pr1
Mon_nt
Month
Pr1
yAr_nt
Year
Pr1
Hd1_nt
First day of week end
Sat
Pr2
Hd2_nt
Second day of week end
Sun
Pr2
iLE_nt
Working days Energy saving starting time
00:00
Pr2
dLE_nt
Working days Energy saving duration
00:00
Pr2
iSE_nt
Holyday Energy saving starting time
00:00
Pr2
dSE_nt
Holyday Energy saving duration
00:00
Pr2
dd1_nt
Sunday defrost
no
Pr2
dd2_nt
Monday defrost
no
Pr2
dd3_nt
Tuesday defrost
no
Pr2
dd4_nt
Wednesday defrost
no
Pr2
dd5_nt
Thursday defrost
no
Pr2
dd6_nt
Friday defrost
no
Pr2
dd7_nt
Saturday defrost
no
Pr2
Ld1_nt
1st defrost starting time
nu
Pr2
Ld2_nt
2nd defrost starting time
nu
Pr2
Ld3_nt
3rd defrost starting time
nu
Pr2
Ld4_nt
4th defrost starting time
nu
Pr2
Ld5_nt
5th defrost starting time
nu
Pr2
Ld6_nt
6th defrost starting time
nu
Pr2
Adr_nt
Serial address
1
Pr2
bAU_nt
Baud rate selection for serial port
9.6
Pr2
onC_nt
ONOFF button configuration
ES
Pr2
on2_nt
ONOFF button timed (3sec) configuration
oFF
Pr2
LG2_nt
Light button timed (3sec) configuration
nU
Pr2
dn2_nt
Down button timed (3sec) configuration
Lnt
Pr2
dP1_nt
Probe P1 value visualization
Pr1
dP2_nt
Probe P2 value visualization
Pr1
dP3_nt
Probe P3 value visualization
Pr1
dP4_nt
Probe P4 value visualization
Pr1
SPd_nt
Instantaneous compressor speed (in Hz)
Pr1
rSE_nt
Real regulation Set Point
Pr1
rEL_nt
Firmware release
Pr1
Ptb_nt
Parameter map code
1
Pr1