Emerson Dixell XR60CHC Installing And Operating Instructions Download Page 6

 

1592033080 XR60CHC EN r1.0 2019.01.30 

                           XR60CHC 

6/6 

 

NTC or PTC:

 ±0.1°C ±1 digit 

PT1000:

 ±0.1°C ±1 digit for probes Pb1, Pb2 and Pb3; ±1.0°C ±1 digit for probe Pb4 

Real time clock:

 data maintenance up to 6 months with lithium battery 

HOT-KEY inputs:

 MAX voltage allowed is 3.3VDC. DO NOT CONNECT ANY EXTERNAL POWER 

SUPPLY. 

20.1

 

STANDARDS 

 

The complete Declaration of Conformity can be found at:  

 

https://dxapp.cloud/ 

20.1.1

 

THE XR60CHC IS COMPLIANT WITH THE FOLLOWING STANDARDS  

ETSI EN 300 328 V2.1.1 (2016-11) 
ETSI EN 301 489-17 V3.1.1 (2016-11) 
IEC EN 60730-2-9: 2008 (Third Edition) and Am.1:2011 in conjunction with IEC 60730-1:2010 (Fourth Edition)  
UL  60730-1  Fourth  Edition  and  CAN/CSA-E60730-1:02  Third  Edition  along  with  its  Amendment  1  dated 
February 2007, the Standards for Automatic electrical controls for household and similar use 

 Part 1: General 

requirements. 
 
It therefore meets the essential requirements of the following Directives: 

Radio equipment Directive 2014/53/EU 
Electromagnetic compatibility 2004/108/EC 
Low Voltage equipment 2006/95/EC 

20.1.2

 

THE XR60CHC IS COMPLIANT WITH THE FOLLOWING STANDARDS 

FCC 15.247 

20.1.3

 

THE XR60CHC IS COMPLIANT TO PART 15 OF THE FCC RULE 

Operation is subject to the following two conditions:  
(1) this device may not cause harmful interference, and  
(2)  this  device  must  accept  any  interference  received,  including  interference  that  may  cause  undesired 

operation.”

 

 
Unauthorized repairs, changes or modifications could result in permanent damage to the equipment and void 
your warranty and your authority to operate this device under Part 15 of the FCC Rules. 

 

NOTE:  This  equipment  has  been  tested  and  found  to  comply  with  the  limits  for  a  Class  A  digital  device, 
pursuant  to  part  15  of  the  FCC  Rules.  These  limits  are  designed  to  provide  reasonable  protection against 
harmful interference when the equipment is operated in a commercial environment. This equipment generates, 
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction 
manual, may cause harmful interference to radio communications. Operation of this equipment in a residential 
area is likely to cause harmful interference in which case the user will be required to correct the interference at 
his own expense. 

20.1.4

 

THE XR60CHC IS COMPLIANT TO RSS 102 

This device complies with Industry Canada RSS-210. Operation is subject to the following two conditions: (1) 
this  device  may  not  cause  interference,  and  (2)  this  device  must  accept  any  interference,  including 
interference that may cause undesired operation of the device. 

 

20.1.5

 

CET XR60CHC INSTRUMENT REPOND AUX NORMES RSS 102 

Le  présent  appareil  est  conforme  aux  CNR  d’Industrie  Canada  applicables  aux  appareils 

radio  RSS-210. 

L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et 
(2)  l’utilisateur  de  l’appareil  doit  accepter  tout  brouillage  radioélectrique  subi,  même  si  le  brouillage  est 
susceptible d’en

 compromettre le fonctionnement. 

21

 

WIRINGS 

21.1

 

XR60CHC, 16+8+8AMP  

 

 

Power Supply (terminals 5-6):

  

110 or 230 Vac @50 or 60Hz 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

21.2

 

XR60CHC, 20+8+5AMP  

 

 

Power Supply (terminals 4-5):

  

110 or 230 Vac @50 or 60Hz 

22

 

BLUETOOTH COMMUNICATION 

 

The controller implements a Bluetooth 4.2 communication module. This gives 
the possibility to communicate with external devices (for example with a mobile 
APP  able  to  recognize  and  decode  the  device).  All  controllers  use  a  unique 
MAC-ADDRESS, which is used both for identification and communication. The 
communication range is about 5 m (worst case, indoor coverage in presence of 
obstacles).  Over  this  distance  it  is  possible  to  suffer  interruptions  in  the 
communication or  quality  degradation  of  the  communication.  A 6-digit  pairing 
secure  code  can  be  required  for  connection.  Please  follow  the  Emerson 
Connected APP instruction for more information. 

22.1

 

FIRST INSTALLATION 

After installation, it will be possible to manage the controller by using the Emerson Connected APP. Il will be 
required to: 

-

 

Install the Emerson Connected APP on your mobile device (smartphone or tablet) 

-

 

Create a new user account before using the APP 

The owner is the only account that can: 

-

 

Manage the controller via Bluetooth 

-

 

Extend rights of access to a specific appliance also to other users 

 
A Cloud portal will be used for: 

-

 

Extend rights of access to a specific appliance also to other users 

-

 

Select the permission level for any new user 

 
The link for opening the Cloud webpage is on the left side menu of the mobile APP (slide right the screen of 
the APP when on the Device List 

page and follow the “Cloud management” link. Please note that the login and 

password for the Cloud webpage are the same of the mobile APP. 

22.2

 

RESET TO FACTORY DEFAULT 

In case a factory reset is required, please follow these operations: 

-

 

Access to the Cloud webpage and select the appliance you want to reset (search for name 
and/or MAC-ADDRESS) 

-

 

Click on the “DELETE” link, the appliance will be removed from the list of owned appliances

 

-

 

Go to the device controller (with the same MAC-ADDRESS) 

-

 

Enter the programming mode 

-

 

Go to the “

b

LE” menu

 

-

 

Select the par. 

rPS

 (reset device ownership) 

-

 

Select “Y” and confirm with SET button

 

-

 

Select the par. 

rLi

 (reset device whitelist) 

-

 

Select “Y” and confirm 

with SET button 

-

 

Exit from the programming menu 

-

 

Logout and login from the mobile APP 

After this, the controller will be reset to factory default configuration and it will be ready for a new association. 
 
 
 

Summary of Contents for Dixell XR60CHC

Page 1: ...NERGY SAVING ALGORITHM The energy saving status will be always saved in the internal memory to resume previous operation if a power failure occurs It needs the presence of a door switch to work for example i1F dor 4 2 1 PARAMETER INVOLVED i1F or i2F set as door input to monitor the appliance usage StE interval to change from normal to energy saving mode EtS interval to change from energy saving to...

Page 2: ...ton 4 To memorise the new set point value push the SET button again or wait for 60 sec 10 3 START A MANUAL DEFROST Push the DEFROST button for more than 3 sec to start a manual defrost 11 PARAMETER MENU The device has a parameter menu available from keyboard and where it is possible to modify some specific parameters A couple of parameter levels are present PR1 user menu standard parameters are pl...

Page 3: ...50 C 67 to 122 F it sets the temperature measured by the evaporator probe dFP which causes the end of defrost idF Interval between two consecutive defrost cycles 0 to 255 hours determines the time interval between the beginnings of two defrosting cycles MdF Maximum length for defrost 0 to 255 min 0 means no defrost when P2P n no evaporator probe presence it sets the defrost duration when P2P Y def...

Page 4: ...ns hundreds of read only n3H Number of relay output 3 activations hundreds of read only n3L Number of relay output 3 activations hundreds of read only n5d Number of daily activations of digital input 1 read only n5H Number of digital input 1 activations thousands of read only n5L Number of digital input 1 activations hundreds of read only n6d Number of daily activations of digital input 2 read onl...

Page 5: ...to abort the operation 17 2 COPY PARAMETERS FROM A HOT KEY DOWNLOAD PARAMETER VALUES 1 Turn OFF the instrument 2 Insert a programmed HOT KEY into the 5 PIN port and then turn the Controller ON 3 The parameter list of the HOT KEY is automatically copied into the controller memory During this operation the do message will blink 4 A flashing End label will inform that the operation was successful 5 R...

Page 6: ...MES RSS 102 Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio RSS 210 L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement 21 WIRINGS 21 1 XR60CHC...

Reviews: