Emerson Dixell XR10CX Installing And Operating Instructions Download Page 4

 

 

1592020010 XR10CX GB m&M r1.1 27.03.2015 

XR10CX 

4/4 

16.

 

CONNECTIONS 

The X-REP

 

output

 

excludes

 the TTL output.. It’s present in the following codes:  

XR10CX- xx

2

xx, XR10CX –xx

3

xx; 

16.1

 

XR10CX – 8A COMPRESSOR 

N.C.

1 2 3

6

7

9 10 11 12

Comp

R

oo

m

8

Hot Key/IV Probe

TTL or X-REP output

8(3)A250V

Line

 

9-40Vdc supply

: connect to the terminals 7 and 8. 

12Vac/dc supply

: connect to the terminals 7 and 8. 

24Vac/dc supply

: connect to the terminals 7 and 8. 

120Vac supply

: connect to the terminals 7 and 8. 

16.2

 

XR10CX – 20A COMPRESSOR 

4 5

6

7

9 10 11 12

Comp

R

oo

m

8

Hot Key/IV Probe

TTL or X-REP output

20(8)A250V

Line

 

9-40Vdc supply

: connect to the terminals 7 and 8. 

12Vac/dc supply

: connect to the terminals 7 and 8. 

24Vac/dc supply

: connect to the terminals 7 and 8. 

120Vac supply

: connect to the terminals 7 and 8. 

17.

 

DEFAULT SETTING VALUES  

Label 

Name 

Range 

°C/°F 

 

Set 

Set point 

LS÷US 

5.0 

- - - 

Hy 

Differential 

0,1

25.5°C/ 1

 255°F 

2.0 

Pr1 

LS 

Minimum set point 

-50°C

SET/-58°F

SET 

-50.0 

Pr2 

US 

Maximum set point 

SET

110°C/ SET 

 230°F 

110 

Pr2 

Ot 

Thermostat probe calibration 

-12

12°C /-120

120°F 

0.0 

Pr1 

P3P 

Third probe presence 

n=not present; Y=pres. 

Pr2 

O3 

Third probe calibration 

-12

12°C /-120

120°F 

Pr2 

P4P 

Fourth probe presence 

n=not present; Y=pres. 

Pr2 

O4 

Fourth probe calibration 

-12

12°C /-120

120°F 

Pr2 

OdS 

Outputs delay at start up 

0÷255 min 

Pr2 

AC 

Anti-short cycle delay 

 50 min 

Pr1 

COn 

Compressor ON time with faulty probe 

 255 min 

15 

Pr2 

COF 

Compressor  OFF  time  with  faulty 
probe 

 255 min 

30 

Pr2 

CH 

Kind of action 

CL=cooling; Ht= heating 

cL 

Pr1 

CF 

Temperature measurement unit 

°C 

 °F 

°C  

Pr2 

rES 

Resolution 

in=integer; dE= dec.point

 

dE  

Pr1 

dLy 

Display temperature delay   

0 ÷ 20.0 min  (10 sec.)  

Pr2 

ALc 

Temperat. alarms configuration 

rE= related to set; 

Ab = absolute 

Ab 

Pr2 

ALU 

MAXIMUM temperature alarm 

Set

110.0°C; Set÷230°F 

110 

Pr1 

ALL 

Minimum temperature alarm 

-50.0°C

Set/ -58°F

Set 

-50.0 

Pr1 

AFH 

Differential for temperat. alarm 
recovery 

(0,1°C÷25,5°C) (1°F÷45°F) 

Pr2 

ALd 

Temperature alarm delay 

 255 min 

15 

Pr2 

dAo 

Delay of temperature alarm at start up 

 23h e 50’ 

1.0 

Pr2 

AP2 

Probe for temperat. alarm of 
condenser 

nP; P1; P2; P3; P4 

P4 

Pr2 

AL2 

Condenser for low temperat. alarm 

(-55 ÷ 150°C) (-67÷ 302°F) 

-40 

Pr2 

AU2 

Condenser for high temperat. alarm 

(-55 ÷ 150°C) (-67÷ 302°F) 

110 

Pr2 

AH2 

Differ.  for  condenser  temp.  alar. 
recovery 

[0,1°C ÷ 25,5°C]  [1°F ÷ 

45°F] 

Pr2 

Ad2 

Condenser temperature alarm delay  

 0 ÷ 254 (min.) , 255=nU 

15 

Pr2 

dA2 

Delay  of  cond.  temper.  alarm at  start 
up 

0.0 ÷ 23h  50’ 

1,0 

Pr2 

bLL 

Compr.  off  for  condenser  low 
temperature alarm 

n(0) - Y(1) 

Pr2 

AC2 

Compr.  off  for  condenser  high 
temperature alarm 

n(0) - Y(1) 

Pr2 

i1P 

Digital input polarity 

oP=opening;CL=closing 

cL 

Pr1 

i1F 

Digital input configuration 

EAL, bAL, PAL, dor; dEF; Htr, 
AUS 

EAL 

Pr1 

did 

Digital input alarm delay 

0÷255min 

Pr1 

nPS 

Number  of  activation  of  pressure 
switch 

0 ÷15  

15 

Pr2 

odc 

Compress status when open door 

no; Fan; CPr; F_C  

no 

Pr2 

rrd 

Regulation restart with door open 
alarm 

n – Y 

Pr2 

HES 

Differential for Energy Saving 

 (-30°C÷30°C) (-54°F÷54°F) 

Pr2 

Adr 

Serial address 

0÷247 

Pr2 

PbC 

Kind of probe 

Ptc; ntc 

ntc 

Pr1 

onF 

on/off key enabling 

nu, oFF; ES 

nu 

Pr2 

dP1 

Room probe display 

-- 

 -- 

Pr1 

dP3 

Third probe display 

-- 

 -- 

Pr1 

dP4 

Fourth probe display 

-- 

 -- 

Pr2 

rSE 

Real set point value 

actual set 

 -- 

Pr2 

rEL 

Software release 

-- 

 -- 

Pr2 

Ptb 

Map code 

-- 

 -- 

Pr2 

 

 
 

Summary of Contents for Dixell XR10CX

Page 1: ...ut to drive the compressor It is also provided with 2 NTC or PTC probe inputs the first one for temperature control the second one optional to connect to the HOT KEY terminals to signal the condenser temperature alarm or to display a temperature The digital input can operate as third temperature probe The HOT KEY output allows to connect the unit by means of the external module XJ485 CX to a netwo...

Page 2: ...With COn 0 compressor is always OFF COF Compressor OFF time with faulty probe 0 255 min time during which the compressor is OFF in case of faulty thermostat probe With COF 0 compressor is always active CH Type of action CL cooling Ht heating DISPLAY CF Temperature measurement unit C Celsius F Fahrenheit WARNING When the measurement unit is changed the SET point and the values of the parameters Hy ...

Page 3: ...able external relay 12 1 PROBE CONNECTION The probes shall be mounted with the bulb upwards to prevent damages due to casual liquid infiltration It is recommended to place the thermostat probe away from air streams to correctly measure the average room temperature Place the defrost termination probe among the evaporator fins in the coldest place where most ice is formed far from heaters or from th...

Page 4: ... cL Pr1 CF Temperature measurement unit C F C Pr2 rES Resolution in integer dE dec point dE Pr1 dLy Display temperature delay 0 20 0 min 10 sec 0 Pr2 ALc Temperat alarms configuration rE related to set Ab absolute Ab Pr2 ALU MAXIMUM temperature alarm Set 110 0 C Set 230 F 110 Pr1 ALL Minimum temperature alarm 50 0 C Set 58 F Set 50 0 Pr1 AFH Differential for temperat alarm recovery 0 1 C 25 5 C 1 ...

Reviews: