Page 2: ......

Page 3: ...this document XEC Supercap should not be exposed to direct sunlight and protected from water and high atmospheric humidity in order to prevent condensation from forming XEC Supercap must not be subjected to mechanical stress vibration and or direct hits Sulfur ammonia smoke and salt can cause corrosion and oxidation XEC Supercap must not be installed in environments containing flammable or explosi...

Page 4: ...th Dixell devices has to be verified in the user manual technical sheet of the device connected to the XEC In case of dubt please contact Dixell Service department Before connecting the device verify that the power supply is compliant with the rating Separate the power of the device from the rest of the electrical devices connected inside the electrical panel XEC Supercap requires a dedicated tran...

Page 5: ... the goods in accordance with local laws Furthermore at the end of the product s life it is also possible to return this to the retailer when a new purchase is made This equipment may contain hazardous substances Improper use or incorrect disposal can have adverse effects on human health and the environment The symbol shown on the product or the package indicates that the product has been placed o...

Page 6: ...1592010460 XEC GB rel 1 0 26 01 2015 XEC 6 16 2 Connections Connector Pin number Description Power input 1 24 Vac Vdc 2 24 Vac Vdc gnd Power output 3 gnd 4 12Vdc ...

Page 7: ...EV20D or IEV24D must be powered by two different transformers the failure of the observance of this rule may result in damage to the XEC Supercap and or the connected device If the XEV20D or IEV24D driver controls two expansion valves two XEC Supercap have to be used For both XEC Supercap respect the same power supply connection terminal 1 of both XEC Supercap has to be connected to the same pole ...

Page 8: ...1592010460 XEC GB rel 1 0 26 01 2015 XEC 8 16 Connection to XEV20D driver and one expansion valve ...

Page 9: ...1592010460 XEC GB rel 1 0 26 01 2015 XEC 9 16 Connection to IEV22D driver and one expansion valve ...

Page 10: ...1592010460 XEC GB rel 1 0 26 01 2015 XEC 10 16 Connection to XEV20D driver and two expansion valves ...

Page 11: ...1592010460 XEC GB rel 1 0 26 01 2015 XEC 11 16 Connection to IEV24D driver and two expansion valves ...

Page 12: ...50 60 Hz Output voltage 12 Vdc 15 0 Power consumption 12VA Max output current 1 2 A max Charging time 1 minute Max current in charging time 350 mA Input output max lenght 50 cm Use AWG18 cables Max number of valves closure after a complete charging time 1 Connectors Screw extractable connector wire 2 5mm 2 ...

Page 13: ...ack IP protection IP20 Product certification Immunity for industrial environments EN61000 6 2 EN61000 6 2 EC EN61000 6 2 IS1 Emission standard for residential commercial and light industrial environments EN61000 6 3 EN61000 6 3 A1 6 Environmental conditions Operating temperature 10 C 60 C Storage temperature 20 C 70 C Relative humidity 20 85 not condensing ...