Delmarva Power Web-Programmable Thermostat Homeowner’s Manual
19
DDWTMS1317B—Delmarva Power IT900 Thermostat Manual
(Version 2 Thermostat with New Screen Shots)
Piece: Manual
Quantity: 000,000
Size: sssss
Colors: ccccc
Finishing: ffffffffff
Mail: mmmmmmm
Program Specific Checklist
Name: Date:
☐
Phone Number
_________ _________
☐
URL
_________ _________
☐
Program Details
_________ _________
GRAPHIC
DESIGNER
☐
SPELL CHECK
CREATIVE
DIRECTOR
PROOFREADER
COPY
SUPERVISOR
COPYWRITER
CREATIVE SERVICES
MANAGER
ACCOUNT
MANAGER
DDWTMS1317B
Delmarva Power IT900 Thermostat Manual (Version 2 Thermostat with New Screen Shots)
Job Opened: November 1, 2013
Requested In-Home Date: December 1, 2013
Latest Revision: November 5, 2013
Approved:
December 4, 2013
Troubleshooting
No Heat or No Cool
Possible Cause
Corrective Action
Thermostat may be in an Energy Wise Rewards
conservation period. “Event in Progress” will be
displayed on top line of home screen.
Wait for the Energy Wise Rewards conservation period
to end.
System switch is set to OFF.
Press the thermostat’s
SYSTEM
button one or more
times to select
HEAT
or
COOL
(as appropriate).
Heat, Cool, or Fan Runs Constantly
Possible Cause
Corrective Action
Fan set to
ON
.
Change Fan to
AUTO
.
Common Problems: No Heat, No Cool, or No Fan
Possible Cause
Corrective Action
Blown fuse or tripped circuit breaker.
Replace fuse or reset breaker.
Furnace power switch set to
OFF
.
Turn switch to
ON
.
Furnace blower compartment door or panel is loose or
not properly installed.
Replace door panel in proper position to engage safety
interlock or door switch.
Thermostat Setting and Thermometer Disagree
Possible Cause
Corrective Action
Thermostat thermometer setting requires adjustment.
The thermometer can be ad/– 5 degrees.
See Adjust Temperature Display on page 9.