100-412-183 REV. 13
93
7.3
Resetting the Power Supply Alarms
You need to reset the weld system when you get an overload. When there is an overload,
the alarm icon appears on the front panel LCD and the General Alarm output on the user
I/O connector becomes active. The procedure for resetting the power supply depends on
the power supply alarm settings. Refer to
Table 7.2 Resetting the DCX S Power Supply
reset procedures.
For more information on interfacing the DCX S Power Supply using the user I/O
Chapter 5: Installation and Setup
Table 7.2
Resetting the DCX S Power Supply
Alarm Setting
Reset Procedure
Latching Alarms
Press the front panel Reset key. You can also send an External
Reset signal.
Non-Latching Alarms Remove and re-apply the start signal.
NOTICE
Alarm circuitry requires at least 20 ms before restarting ultrasonic
power.
Summary of Contents for DCX S
Page 4: ...iv 100 412 183 REV 13 ...
Page 22: ...12 100 412 183 REV 13 ...
Page 36: ...26 100 412 183 REV 13 ...
Page 47: ...100 412 183 REV 13 37 4 3 Declaration of Conformity Figure 4 1 Declaration of Conformity ...
Page 50: ...40 100 412 183 REV 13 ...
Page 54: ...44 100 412 183 REV 13 Figure 5 1 DCX S Power Supply Benchtop Dimensional Drawing ...
Page 86: ...76 100 412 183 REV 13 ...
Page 87: ...100 412 183 REV 13 77 Chapter 6 Converters and Boosters 6 1 Converters and Boosters 78 ...
Page 120: ...110 100 412 183 REV 13 ...
Page 137: ...100 412 183 REV 13 127 8 5 Circuit Diagram Figure 8 2 Interconnect Diagram Power Supply ...
Page 144: ...134 100 412 183 REV 13 ...
Page 145: ...100 412 183 REV 13 135 Appendix A Timing Diagrams A 1 Timing Diagrams 136 ...
Page 147: ...100 412 183 REV 13 137 Appendix B Signal Diagrams B 1 Signal Diagrams 138 ...
Page 154: ...144 100 412 183 REV 13 ...