background image

READ AND SAVE THESE INSTRUCTIONS

Installation Instruction on

New CSA Hanging Device

Always properly install the ceiling fan mounting plate to a structural ceiling joist that is capable of
reliably supporting at least 50 pounds. 

INSTALLATION INSTRUCTIONS

1.

Slip the loop of the short steel support cable onto the flat
washer, lockwasher and 2” lag screw (supplied). Attach
the short steel support cable through the center hole of
the outlet box into the supporting joist by securely
tightening the flat washer, lockwasher and 2” lag screw
(Figure 1). The support cable lag screw must be installed
such that it is structurally independent of the outlet box.
Pre-drill the support joist with a 9/64” diameter drill to
prevent splitting the joist.

2.

Pull the electrical supply wires and support cable through
the center opening of the ceiling cover (Figure 2).

3.

Install the ceiling cover and hanger bracket together onto
the outlet box using the two screws supplied with the
ceiling fan. Discard the screws that were supplied with
the electrical box. The hanger bracket will nest into the
ceiling cover between the raised guides on the bottom
surface of the cover. The center hole of the ceiling cover
provides visual access to view installation of the outlet
box screws into the threaded mounting holes of the box
(Figure 3).

4.

Pull the electrical supply wires and support cable through
the opening on the back side of the hanger bracket for
installation of the fan’s hanger ball.

PRELIMINARY PROCEDURES FOR

EXTRA SUPPORT HANGING SYSTEM

SHORT STEEL 
SUPPORT CABLE

JOIST

2" LAG SCREW

FLAT WASHER

LOOP

CENTER HOLE

LOCKWASHER

FLAT WASHER, 
LOCKWASHER, & 
2" LAG SCREW

DRYWALL CEILING

SHORT STEEL 
SUPPORT CABLE

OUTLET BOX

ELECTRIC

OUTLET BOX

Figure 1

Turning off wall switch is not sufficient.
To avoid possible electrical shock, be sure
electricity is turned off at the main fuse box before
wiring. All wiring must be in accordance with
National and Local codes and the ceiling fan must
be properly grounded as a precaution against
possible electrical shock.

WARNING

!

MOUNTING SCREW (2)

TAB

HANGER BRACKET

CEILING 
COVER

Figure 2

To avoid possible fire or shock, do not pinch electrical
wires between the ceiling cover and hanger bracket, or the
electrical box and the ceiling cover.

WARNING

!

Summary of Contents for CORSAIR 44"

Page 1: ...F3400 READ AND SAVE THESE INSTRUCTIONS Net Weight Lbs CORSAIR 44 or 52 Ceiling Fan Owner s Manual CF3400AP Antique Pewter CF3400ORH Oil Rubbed Bronze with Highlights Model Numbers 24 21 4 36 22 9 48 24 5 BP7386 CF3400 Corsair 11 25 09 6 20 AM Page 1 ...

Page 2: ...xes listed as Acceptable for Fan Support and use the mounting screws provided with the outlet box Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced Consult a qualified electrician if in doubt 4 The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades 5 Foll...

Page 3: ... Page 5 If you feel you do not have enough wiring knowledge or experience have your fan installed by a licensed electrician WARNING Unpacking Instructions For your convenience check off boxes are provided next to each step As each step is completed place a check mark in the box This will insure that all steps have been completed and will be helpful in finding your place should you be interrupted A...

Page 4: ...ution against possible electrical shock WARNING To avoid possible fire or shock follow all wiring instructions carefully Any Electrical work not described in these instructions should be done or approved by a licensed electrician WARNING Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker box before wiri...

Page 5: ...installation of the outlet box screws into the threaded mounting holes of the box Figure 2 This product is designed to use only those parts supplied with this product and or any accessories designated specifically for use with this product by Emerson Electric Co Substitution of parts or accessories not designated for use with this product by Emerson Electric Co could result in personal injury or p...

Page 6: ...mounting holes of the medallion and securely tighten each screw Figure 6 If using wooden blades be very careful not to over tighten the blade screws NOTE Screws for the wooden blades are shipped with the blades Do not discard the blade packaging until you have located the screws NOTE Recommend the blades screws be checked regularly for tightness Check to see that all connections are tight includin...

Page 7: ...wire from existing fan wall switch Figure 7 3 Slide the fan control to the OFF position 0 Turning off wall switch is not sufficient To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker box before wiring All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible ele...

Page 8: ... turning then slide the reversing switch to the opposite position and turn fan on again Figure 11 4 The fan blades will turn in the opposite direction and reverse the airflow 4 0 3 2 1 Figure 11 REVERSE SWITCH 8 Model No CF3400 7 Attach the fan control to the wall outlet box with two 6 32 x 3 4 screws provided with control 8 Position the wall plate provided with control onto the speed control Usin...

Page 9: ...re or catalog Do not use water when cleaning your ceiling fan It could damage the motor or the blades and create the possibility of an electrical shock WARNING The use of any other control not specifically approved for this fan could result in fire shock and personal injury WARNING This product is designed to use only those parts supplied with this product and or any accessories designated specifi...

Page 10: ...8 763898 5 Axillary Capacitor 8 0 uF 1 763948 763948 6 Motor Assembly K55XL 1 763820 763820 7 Medallions set of two 763897 AP 763897 ORH 8 Finial Cover 1 763838 AP 763838 ORH 9 SW46 Wall Control 1 761971 761971 Parts Bag Containing 763828 763828 10 Connectors Wire 12 Ga 4 11 10 32 x 75 Oval Head Screws 7 12 8 32 x 25 Flat Head Screws 4 Owner s Manual 1 BP7386 BP7386 Repair Parts Listing BP7386 CF3...

Page 11: ...ave been removed HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION The model number of your Fan will be found on a label attached to the top housing For repair parts phone 1 800 654 3545 PART NUMBER NAME OF ITEM PART DESCRIPTION MODEL NUMBER BP7386 CF3400 Corsair 11 25 09 6 20 AM Page 11 ...

Page 12: ...l 1 800 654 3545 for the address of the nearest authorized service center You will be responsible for all insurance freight or other transportation charges to our factory or authorized service center Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage What Is Not Covered The glass globes and light bulbs of y...

Page 13: ...ical box The hanger bracket will nest into the ceiling cover between the raised guides on the bottom surface of the cover The center hole of the ceiling cover provides visual access to view installation of the outlet box screws into the threaded mounting holes of the box Figure 3 4 Pull the electrical supply wires and support cable through the opening on the back side of the hanger bracket for ins...

Page 14: ...ON ELECTRIC CO 8100 W Florissant St Louis MO 63136 5 Install the assembled ceiling fan onto the mounting bracket in accordance with the instructions provided with the ceiling fan 6 Unscrew the machine screw from the brass nut supplied and feed the end of the ceiling fan support cable from the ceiling fan downrod through the loop on the end of the short steel support cable Figures 4 and 5 BRASS NUT...

Reviews: