Our measuring instruments are inspected before shipment to ensure the accuracy. In 
order to ensure the high measurement accuracy of instrument, we recommend that you 
regularly calibrate the instrument.

Calibration

You have the following options: 
1. Return to Emerson for calibration. 
2. The user calibrates himself during frying process.

We recommend that you measure the unexpanded edible oil after it is heated to 50°C 
when first using a new instrument. It is best to perform multiple measurements in 
succession and repeat, and record the TPM value for each measurement. The average 
of these readings will be the reference for your future calibration. In the future, when 
calibrating the instrument, the unfried cooking oil is heated to 50°C and calibrated with 
the previously recorded calibration reference value.

Please note that the reference values described will need to be re-recorded when 
replacing other types of cooking oil or changing the supplier of cooking oil.

The following is used to record your calibration values:

The type of measured oil is: ________________________ 
 
The calibration reference value is: ________________________

1.2. Use conditions of instrument 

a. Power source: polymer lithium battery (3.7V) 
b. Rated power: 0.45W 
c. Operating temperature: -20° to 50°

 

C (-4° to 32°

 

F) 

d. Relative humidity: 30% to  80% (no condensation) 
e. Storage temperature: -20° to 70°

 

C (-4° to 158°F)

2

Summary of Contents for Cooper-Atkins 20900

Page 1: ...Instruction Guide Cooking Oil Tester Cooper AtkinsTM Model No 20900 ...

Page 2: ...2 Working principle 3 3 Main performance 4 3 1 Technical indicators 4 3 2 Technical Specifications 4 4 Installation adjustment 4 4 1 Unpacking inspection 4 4 2 Installation conditions 5 4 3 Installation steps 5 5 Use and operation 5 5 1 Introduction of function 5 5 2 Security measures 5 9 5 3 Instrument Settings 6 8 8 9 5 4 Sample test 5 5 Shutdown operation i ...

Page 3: ...ly maintenance of the instrument 7 1 Cleaning probe 12 7 2 Cleaning the outer casing 12 7 3 Calibration instrument 13 8 Storage and transportation 13 9 Out of factory instructions 14 10 Consumables and spare parts 15 11 Environmental protection notice 15 ii ...

Page 4: ...such as probes and connecting rods during use Warning The instrument cannot be used in an electromagnetic environment Please turn off induction cookers and other equipment when using it Warning The instrument should be used within the specified range It is easy to damage the instrument if it is out of range Note If the instrument fails do not use it contact Emerson customer service Note Emerson Co...

Page 5: ...trument be used to detect In principle all oils and fats that are fried can be measured Vegetable oils such as canola oil soybean oil sesame oil palm oil olive oil and peanut oil can also be measured Depending on type of fat the TPM of fresh oil will fluctuate between a few percent The maximum use time of frying oil will vary The acid value is used to evaluate the quality of unfried oil This instr...

Page 6: ...se readings will be the reference for your future calibration In the future when calibrating the instrument the unfried cooking oil is heated to 50 C and calibrated with the previously recorded calibration reference value Please note that the reference values described will need to be re recorded when replacing other types of cooking oil or changing the supplier of cooking oil The following is use...

Page 7: ...oils used for frying undergo a series of physical and chemical changes during high temperature frying which produce substances that are harmful to health Probe Rod Charging Indicator HOLD key manually save reading data configure DOWN key set the adjustment value and option of menu POWER key power switch of instrument UP key used to set up the adjustment value of menu and option Display Control But...

Page 8: ...ature 0 to 200 C 32 to 392 F TPM 0 to 50 Measurement accuracy temperature 1 C 2 F TPM 2 Resolution Temperature 0 1 C F TPM 0 1 Power supply polymer lithium battery 3 7V charging method USB Temperature sensor PTC sensor f TPM sensor capacitive sensor g Communication interface Micro USB Wi Fi Bluetooth h Data printing Bluetooth printer optional i Data storage Supports 10 000 measurement data storage...

Page 9: ...g electromagnetic field interference at the work site 4 3 Installation steps 1 It is recommended to fully charge the instrument before using it for the first time 2 Remove the probe cover before use and wipe the sensor clean with test paper 5 Use and operation 5 1 Introduction of function Power on Press power key 1 second the instrument turns on the display lights up the boot initialization interf...

Page 10: ...atically locked after the data measurement is stable which is convenient for observing and recording data Hold Data lock function indicates that the data is locked and no longer changes TPM TPM data indicator 25 0 C The temperature value shows the temperature of current measurement environment There are two modes C and F The temperature display range is 0 200 C 32 F to 392 F and the value does not...

Page 11: ...For TPM calibration use the instrument to measure the edible oil with known TPM value Modify the value to calibrate the temperature sensor and adjust the value by Up and Down TPM Upper Upper limit value of TPM alarm when the TPM value reaches this value the background color of the screen turns red When TPM value belows this value the background color of the screen turns orange TPM Lower Lower limi...

Page 12: ...ent See the cleaning instructions of probe for details 3 Try to avoid touching the probe with metal objects For example frying baskets pot walls because these things may affect the measurement results the minimum spacing from metal objects is at least 1cm 4 Uneven oil temperature in the frying oil may cause measurement errors Please stir the instrument quickly in the frying oil 5 If the measuremen...

Page 13: ...frying oil will automatically maintain the measured data which will make it easy to observe and record the data 5 5 Shutdown operation 1 After each use of the instrument press the power key to turn off the instrument 2 After waiting for the probe temperature to cool down to around room temperature wipe off the sensor surface and the grease on the probe by test paper Insert the probe cover onto the...

Page 14: ... 2 When using the computer to configure the instrument there is no COM port Poor connection of data lines The USB driver corresponding to the computer is not installed Unplug the data cable and reconnect it Install the CP2102 driver of the corresponding system download it yourself or contact our sales staff to request the driver 3 Data in the air is abnormal TPM is not 0 1 The sensor cover is not ...

Page 15: ...rameters are not set correctly Configure the Wi Fi parameters of instrument using the corresponding configuration software If not resolved please call our technical staff to solve the problem 6 Connection for bluetooth printer is abnormal Parameters of Bluetooth printer are not set correctly Use it when the printer is not initialized 1 Configure the parameters of Bluetooth printer by corresponding...

Page 16: ...a soft tissue Cold oil slag cleaning for probe surface 1 Insert the probe into the hot oil 2 Cool the probe and probe rod until there is no risk of burns 3 Repeat the 3 5 steps to clean the probe before the oil residue cools 7 2 Cleaning the outer casing Make sure the instrument is off before cleaning the instrument case 1 Do not use sharp objects 2 Do not use aggressive detergents and solvents 3 ...

Page 17: ...on to the immersion depth 5 In order to get the reading faster stir the probe in the oil read the display data and record it after temperature is stable The TPM adjustment value is calculated by comparing the previously recorded calibration values Modify the TPM value to be adjusted by the TPM Adjustment Value menu in the setup menu then press Hold key 1 second to save and exit the menu Turn off t...

Page 18: ...void water splashes rain and direct sunlight Storage temperature and humidity meet the requirements Avoid corrosive gases and salty air Avoid strong electric fields and strong magnetic fields There is no severe vibration impact and pests in the storage place 9 Out of Factory Instructions This product can be repaired within one year from the date of sale it is subject to the date of invoice issued ...

Page 19: ...unsorted general waste Improper handling can harm the environment and human health Please refer to local regulations for collection and disposal equipment of waste disposal Emerson Commercial Residential Solutions 356 Chisholm Road Auburn NSW 2144 Australia Tel 612 9795 2800 Fax 612 9738 1699 Climate Emerson com Asia Cooper Atkins Emerson Commercial Residential Solutions 33 Reeds Gap Road Middlefi...

Reviews: