background image

Product Data Document

420DS-12A

October 1, 2007 - Page 5

Integrated Pump Control 

SCADA RTU

Website:  www.EmersonProcess.com/Remote

Remote Automation Solutions

Software components

The ControlWave pump control application is 

available pre-installed in a ControlWave Micro or 

Express PLC/RTU.  A modifiable version is avail

-

able allowing program additions, but does not allow 

modifications to the pump control program itself. 

There is also a complete source version that allows 

unlimited modification of the pump control program. 

These three offerings provide the flexibility to meet 

the needs of wide range of users, technicians and 

engineers.

Products for expanded functionality

The pump control SCADA package can be com-

bined with a variety of additional products that facili-

tate integration or provide even greater functionality.

Process Measurement Transmitters

Bristol 2808 & 3808

2808 analog pressure transmitter for tank level 

• 

measurement

3808 digital DP transmitter for flow 

• 

measurement
Adjustable ranges

• 

High accuracy

• 

Two year warranty

• 

Local indicator option

• 

KPSI™ Submersible Level Transducers

Tank and wet well level measurement

• 

5 to 700 feet

• 

.05% to 1 % full scale accuracy

• 

Non-fouling diaphragm options for lift station 

• 

applications
4-20 mA or 0-5 V output

• 

AquaSensors™ Water Quality Instruments

The AquaSensors DataStick™ provides a cost-ef-

fective plug and play analytical measurement sys-

tem for continuous use in industrial environments.  

DataStick communicates with ControlWave via a 

preconfigured serial Modbus function block.

Direct measurement of pH, reagent free residual 

• 

chlorine, dissolved oxygen, ORP or turbidity

11” CPVC direct insertion probe

• 

10-30 Vdc, <200 mW

• 

Censar® Six-Cense® 

multiparameter in-line sensor 

measures in real time (pH, ORP, conductivity, dis-

solved oxygen, free chlorine, and temperature) 

Direct insertion into pressurized main 2 inches 

• 

to 72 inches in diameter
Operates under working pressures up to 230 psi

• 

Reagent-free measurement of Chlorine

• 

Measures Monochloramine for plans using 

• 

chloramination
Low maintenance, low cost sensor replacement

• 

Security Vision application package

Pre and post event video capture and replay

• 

Pre-programmed function block provides all 

• 

video file/folder manipulation

OpenBSI Utility for collection and replay of 

• 

captured events
IP enabled network video camera with FTP 

• 

server
Facility entry access control and reporting

• 

Summary of Contents for Control Wave SCADA RTU

Page 1: ...o maintain level pressure and or flow Some sites may also have the need to control chemical feed measure rain level and detect intrusion events All of these are pre programmed and available for use to customize for the specific site When the application requires modifications or addi tions to the standard program Bristol ControlWave Designer allows unlimited customization by your engineering staff...

Page 2: ... 2 tank level DI Intrusion or Motion Digital outputs Pump 1 2 start Pump 1 2 Stop Analog inputs Station flow Inlet pressure Outlet pressure Chlorine residual Clearwell level or tank level Analog outputs VFD speed control Chemical feed pump Counter inputs Station flow Rain gauge Triplex Booster or Lift Station Digital inputs Pump 1 2 3 status Pump 1 2 3 Remote Local 2 tank level DI Intrusion or Mot...

Page 3: ...icantly benefiting radio and cellular network architectures Daily Archive Stores 35 days of time stamped minimums maxi mums averages and totals Hourly Archive Stores hourly time stamped minimums maximums averages and totals Trend Archive The Trend Archive stores instantaneous values at a fixed period from one minute to sixty minutes Setup and Configuration As mentioned earlier the ControlWave pump...

Page 4: ... taneous values of pressure flow and level Setup and configuration may also be performed from the integral display keypad on the ControlWave PLC RTU SCADA package or via the SCADA system host HMI All configuration parameters are made available to OPC servers for compatibility with our OpenEnterprise SCADA software as well as third party SCADA software packages The configuration pages allow you to ...

Page 5: ...nsducers Tank and wet well level measurement 5 to 700 feet 05 to 1 full scale accuracy Non fouling diaphragm options for lift station applications 4 20 mA or 0 5 V output AquaSensors Water Quality Instruments The AquaSensors DataStick provides a cost ef fective plug and play analytical measurement sys tem for continuous use in industrial environments DataStick communicates with ControlWave via a p...

Page 6: ...prove the designs or specifications of such products at any time without notice All sales are governed by RAS terms and conditions which are available upon request RAS does not assume responsibility for the selection use or maintenance of any product Responsibility for proper selection use and maintenance of any RAS product remains solely with the purchaser and end user OpenEnterprise SCADA Host T...

Reviews: